Belden 18 AWG Pairs Overall Beldfoil Shielding Exposed Run Green Insulated Ground Wire UL Instrumentation 600V Tray Cable

Belden 18 AWG Pairs Overall Beldfoil Shielding Exposed Run Green Insulated Ground Wire UL Instrumentation 600V Tray Cable

Select gauge from drop-down menu for prices:

Belden 18 AWG Pairs Overall Beldfoil Shielding Exposed Run Green Insulated Ground Wire UL Instrumentation 600V Tray Cable

Product Details

Reliability – even in the harshest of environments – is the hallmark of Belden instrumentation cables.

No matter what gauge size, conductor count, insulation, jacket, armor or rating, Belden meets your need for reliability, performance, security and long life — guaranteed.

Benefits:
• Savings on material, labor and maintenance with cables rated for exposed runs — no need for conduit
• Superior electrical performance and longer runs in dozens of different environments
• Assured, flexible installation connections with all the necessary ratings

Features:
• Jacket options for excellent resistance to oil, outdoor sunlight/UV, flame and extreme temperatures
• Insulation options for excellent wet electrical performance, oil and chemical resistance and extreme temperature flexiblity
• Conductor options to provide increased flexibilty, greater flex life and corrosion resistance

Ground Wire:
• Ground Wire (Y/N): Y
• Ground Wire AWG: 18
• Ground Wire Stranding: 7x26
• Ground Wire Conductor Material: BC - Bare Copper
• Ground Wire Insulation Material: PVC/Nylon - Polyvinyl Chloride/Nylon

Insulation:
• Material: PVC/Nylon - Polyvinyl Chloride/Nylon

Inner Shield Drain Wire AWG:
• AWG: 20
• Stranding: 7x28
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 1.2192
• Outer Jacket Ripcord: Yes

Mechanical Charactertistics (Overall):
• Wet Temperature Range: -30°C To +75°C
• Dry Temperature Range: -30°C To +90°C
• Bulk Cable Weight: 56 lbs/1000 ft.
• Max. Recommended Pulling Tension: 80 lbs.
• Min. Bend Radius/Minor Axis: 3.400 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: NPLF, TC-ER, UL 1277
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 09/23/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: ICEA S-73-532, S-61-402

Electrical Characteristics (Overall):
• Nom. Inductance (?H/ft): 0.1945
• Nom. Capacitance Conductor to Shield (pF/ft): 74.3
• Nom. Mutual Capacitance (pF/ft): 41.3
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 5.86
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 7.46
• Max. Operating Voltage - UL: 600 V RMS (NEC Type TC)
• Max. Operating Voltage - UL: 150 V RMS (NPLF)

Flame Test:
• UL Flame Test: UL1685 UL Loading
• C(UL) Flame Test: FT4
• IEEE Flame Test: 1202
• ICEA Flame Test: T-29-520

Suitability:
• Suitability - Burial: Yes
• Sunlight Resistance: Yes

Plenum/Non-Plenum:
• Plenum (Y/N): No

awg # pairs overall cable-
nominal
dia. (mm)
belden cable
part number
Action
18 1 8.636 3088AE Request A Quote
18 1 8.636 3088CE Request A Quote

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.