Belden 18 AWG Pairs 300V PLTC Overall Beldfoil Shielding Cable
Select gauge from drop-down menu for prices:
- Belden 9318 18 AWG 1 Pair 300V PLTC Multi Conductor Cable
- Belden 9552 18 AWG 2 Pairs 300V PLTC Multi Conductor Cable
- Belden 9553 18 AWG 3 Pairs 300V PLTC Multi Conductor Cable
- Belden 9554 18 AWG 4 Pairs 300V PLTC Multi Conductor Cable
- Belden 9556 18 AWG 6 Pairs 300V PLTC Multi Conductor Cable
- Belden 9559 18 AWG 9 Pairs 300V PLTC Multi Conductor Cable
- Belden 9563 18 AWG 11 Pairs 300V PLTC Multi Conductor Cable
- Belden 9565 18 AWG 15 Pairs 300V PLTC Multi Conductor Cable
Product Details
Combine noise protection with flexibility by choosing Type PLTC/ITC cables. Ideally, these cables are used in power-limited circuits for industrial control and energy management systems as well as intercom, audio and alarm applications.
No matter what gauge size, conductor count, insulation, jacket, armor or rating, Belden can meet your needs.
Benefits:
• Savings on material, labor and maintenance with cables rated for exposed runs — no need for conduit
• Superior electrical performance and longer runs in dozens of different environments
• Assured, flexible installation connections with all the necessary ratings
Features:
• Jacket options for excellent resistance to oil, outdoor sunlight/UV, flame and extreme temperatures
• Insulation options for excellent wet electrical performance, oil and chemical resistance and extreme temperature flexiblity
• Conductor options to provide increased flexibilty, greater flex life and corrosion resistance
Insulation:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness (mm): 0.432
Outer Shield Drian Wire AWG:
• AWG: 20
• Stranding: 19x32
• Material: TC - Tinned Copper
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.9398
• Outer Jacket Ripcord: Yes
Mechanical Charactertistics (Overall):
• Operating Temperature Range: -30°C To +105°C
• UL Temperature Rating: 105°C
• Bulk Cable Weight: 47.622 Kg/Km
• Max. Recommended Pulling Tension: 115.653 N
• Min. Bend Radius/Minor Axis: 56.642 mm
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMG, ITC-ER, PLTC-ER
• CEC/C(UL) Specification: CMG
• AWM Specification: UL Style 2464 (300 V 80°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Electrical Characteristics (Overall):
• Nom. Inductance (?H/m): 0.55777
• Nom. Capacitance Conductor to Shield (pF/m): 328.1
• Nom. Capacitance Conductor to Conductor (pF/m): 177.174
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 19.5548
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/km): 29.529
• Max. Operating Voltage - UL: 300 V RMS (PLTC, CMG)
• Max. Operating Voltage - UL: 150 V RMS (ITC)
• Max. Recommended Current: 5.5 Amps/Conductor @ 25°C
Flame Test:
• UL Flame Test: UL1685 UL Loading
• C(UL) Flame Test: FT4
• IEEE Flame Test: 1202
Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes
• Sunlight Resistance: Yes
Plenum/Non-Plenum:
• Plenum (Y/N): No
awg | # pairs | overall cable- nominal dia. (mm) |
belden cable part number |
Action |
18 | 1 | 5.918 | 9318 | Request A Quote |
18 | 2 | 9.347 | 9552 | Request A Quote |
18 | 3 | 10.439 | 9553 | Request A Quote |
18 | 4 | 11.455 | 9554 | Request A Quote |
18 | 6 | 12.624 | 9556 | Request A Quote |
18 | 9 | 14.707 | 9559 | Request A Quote |
18 | 11 | 16.891 | 9563 | Request A Quote |
18 | 15 | 18.771 | 9565 | Request A Quote |