General Cable FREP® FR-EPR CPE Type TC Individual and Overall Shielded Triads Instrumentation Shielded 600V UL

General Cable FREP® FR-EPR CPE Type TC Individual and Overall Shielded Triads Instrumentation Shielded 600V UL

Select gauge from drop-down menu for prices:

General Cable FREP® FR-EPR CPE Type TC Individual and Overall Shielded Triads Instrumentation Shielded 600V UL
FREP FR-EPR CPE Type TC Individual and Overall Shielded Triads Instrumentation Shielded 600V UL

Conductor:
• 18 AWG and 16 AWG tinned, annealed copper per ASTM B33
• Class B stranding per ASTM B8

Insulation:
• Flame-Retardant Ethylene Propylene Rubber (FR-EPR) Type II
• Color-coded per ICEA Method 1: Triads - black, white and red. One conductor in each triad is printed alpha-numerically for easy identification

Shield:
Individual and overall shielded triads:
• Individual triads are 100% shielded with Flexfoil® aluminum/polyester in contact with stranded tinned copper drain wire
• Overall shield is Flexfoil® aluminum/polymer in contact with stranded tinned copper drain wire

Jacket: Lead-free, flame-retardant, thermoplastic Chlorinated Polyethylene (CPE)

Applications:
• In free air, raceways or direct burial
• In wet or dry locations
• Permitted for use in Class I, Division 2 industrial hazardous locations per NEC

Features:
• Rated at 90?C wet or dry
• Ripcord applied to all cables with jacket thickness of 60 mils or less
• Excellent physical, thermal and electrical properties
• Excellent moisture resistance
• Excellent resistance to compression cuts and heat deformation
• Excellent flame resistance—burns to an ash; does not exhibit thermoplastic drip
• Low coefficient of friction for easy pulling
• Sunlight- and weather-resistant
• Excellent low temperature cold bend characteristics
• Meets cold bend test at -40?C

Compliances:
Industry Compliances:
• UL 1277 Type TC, UL File # E57179
• UL 1581
• ICEA S-73-532/NEMA WC57
• RoHS Compliant

Flame Test Compliances:
• UL 1581/UL 2556 VW-1
• UL 1685 Vertical Flame Test
• IEEE 383
• IEEE 1202
• CSA FT4
• ICEA T-29-520

Other Compliances:
• EPA 40 CFR, Part 261 for leachable lead content per TCLP
• OSHA Acceptable

Packaging: Material cut to length and shipped on non-returnable wood reels

cond. Size (AWG) No. of pairs Net weight General cable part number Action
Lbs/1000Ft Kg/Km
18 awg conductors
18 2 tri 127 189 337150* Request a Quote
18 4 tri 201 299 319250* Request a Quote
18 8 tri 343 510 319260* Request a Quote
18 12 tri 528 786 337160* Request a Quote
18 16 tri 675 1005 294540* Request a Quote
18 20 tri 825 1228 337170* Request a Quote
18 24 tri 972 1447 337180* Request a Quote
18 36 tri 1470 2188 337190* Request a Quote
16 awg conductors
16 2 tri 159 237 280950* Request a Quote
16 4 tri 249 371 280960* Request a Quote
16 8 tri 472 702 280970* Request a Quote
16 12 tri 683 1016 287410* Request a Quote
16 16 tri 879 1308 337200* Request a Quote
16 20 tri 1058 1575 337210* Request a Quote
16 24 tri 1266 1884 337220* Request a Quote
16 36 tri 1918 2854 337230* Request a Quote