Product Details
Belden® paired cable products are manufactured in a variety of gage sizes, dimensions, insulation materials, shielding configurations, and jacketing materials including Plenum and High-Temperature versions to meet the technical requirements of many different types of systems.
Paired cables allow balanced signal transmission, which results in lower crosstalk through common mode rejection. Due to the improved noise immunity of twisted pairs, they generally permit higher data speeds than multi-conductor cables.
Insulation:
• Material: PE - Polyethylene
• Wall Thickness (mm): 0.406
Outer Shield Drain Wire AWG:
• AWG: 24
• Stranding: Stranded
• Material: TC - Tinned Copper
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.889
Mechanical Charactertistics (Overall):
• Operating Temperature Range: -30°C To +80°C
• UL Temperature Rating: 80°C (UL AWM Style 2919)
• Bulk Cable Weight: 59.528 Kg/Km
• Max. Recommended Pulling Tension: 253.547 N
• Min. Bend Radius/Minor Axis: 76.200 mm
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CM
• CEC/C(UL) Specification: CM
• AWM Specification: UL Style 2919 (30 V 80°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 100
• Nom. Capacitance Conductor to Conductor (pF/m): 50.8555
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/m): 90.2275
• Nominal Velocity of Propagation (VP %): 66
• Nominal Delay (ns/m): 5.2496
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 78.744
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/km): 14.4364
• Max. Operating Voltage - UL: 30 V RMS (UL AWM Style 2919)
• Max. Operating Voltage - UL: 300 V RMS (CM)
• Max. Recommended Current: 2.1 Amps/Conductor @ 25°C
Flame Test:
• UL Flame Test: UL1685 UL Loading
Plenum/Non-Plenum:
• Plenum (Y/N): No
awg | # pairs | overall cable- nominal dia. (mm) |
belden cable part number |
Action |
24 | 2 | 7.391 | 9829 | Request A Quote |
24 | 3 | 7.747 | 9830 | Request A Quote |
24 | 4 | 8.382 | 9831 | Request A Quote |
24 | 5 | 8.585 | 9832 | Request A Quote |
24 | 6 | 9.246 | 9839 | Request A Quote |
24 | 7 | 9.296 | 9833 | Request A Quote |
24 | 9 | 10.643 | 9834 | Request A Quote |
24 | 10 | 11.455 | 9835 | Request A Quote |
24 | 12 | 11.786 | 9836 | Request A Quote |
24 | 18 | 14.402 | 9837 | Request A Quote |
24 | 25 | 17.018 | 9838 | Request A Quote |
24 | 2 | 6.858 | 8102 | Request A Quote |
24 | 3 | 7.188 | 8103 | Request A Quote |
24 | 4 | 7.087 | 8104 | Request A Quote |
24 | 5 | 7.696 | 8105 | Request A Quote |
24 | 6 | 8.661 | 8106 | Request A Quote |
24 | 7 | 6.858 | 8107 | Request A Quote |
24 | 8 | 9.398 | 8108 | Request A Quote |
24 | 10 | 10.846 | 8110 | Request A Quote |
24 | 12 | 11.176 | 8112 | Request A Quote |
24 | 15 | 12.116 | 8115 | Request A Quote |
24 | 18 | 13.640 | 8118 | Request A Quote |