Belden 16 AWG Triads Individually and Overall Beldfoil Shielding UL Instrumentation 600V Tray Cable

Belden 16 AWG Triads Individually and Overall Beldfoil Shielding UL Instrumentation 600V Tray Cable

Product Details

Reliability – even in the harshest of environments – is the hallmark of Belden instrumentation cables.

No matter what gauge size, conductor count, insulation, jacket, armor or rating, Belden meets your need for reliability, performance, security and long life — guaranteed.

Benefits:
• Savings on material, labor and maintenance with cables rated for exposed runs — no need for conduit
• Superior electrical performance and longer runs in dozens of different environments
• Assured, flexible installation connections with all the necessary ratings

Features:
• Jacket options for excellent resistance to oil, outdoor sunlight/UV, flame and extreme temperatures
• Insulation options for excellent wet electrical performance, oil and chemical resistance and extreme temperature flexiblity
• Conductor options to provide increased flexibilty, greater flex life and corrosion resistance

Insulation:
• Material: PVC/Nylon - Polyvinyl Chloride/Nylon

Inner Shield:
• Trade Name: Beldfoil®
• Type: Tape
• Material: Aluminum Foil-Polyester Tape

Inner Shield Drain Wire AWG:
• AWG: 18
• Stranding: 7x26
• Material: TC - Tinned Copper

Outer Shield Drain Wire AWG:
• AWG: 16
• Stranding: 7x24
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 1.5435
• Outer Jacket Ripcord: Yes

Overall Cabling Lay Length and Direction:
• Length (in.): 7.000
• Twists (twist/ft): 1.710

Pair Lay Length and Direction:
• Lay Length (in.): 3.000
• Twists (twist/ft): 4.000

Mechanical Charactertistics (Overall):
• Wet Temperature Range: -30°C To +75°C
• Dry Temperature Range: -30°C To +90°C
• Bulk Cable Weight: 254.700 lbs/1000 ft.
• Max. Recommended Pulling Tension: 554 lbs.
• Min. Bend Radius/Minor Axis: 6.400 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: NPLF, TC-ER
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: ICEA S-73-532, S-61-402

Electrical Characteristics (Overall):
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 3.67
• Nom. Inner Shield DC Resistance @ 20°C (Ohm/1000 ft): 4.99
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 3.07
• Max. Operating Voltage - UL: 600 V RMS (NEC Type TC)
• Max. Operating Voltage - UL: 150 V RMS (NPLF)

Flame Test:
• UL Flame Test: UL1685 UL Loading
• CSA Flame Test: FT4
• IEEE Flame Test: 1202

Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes
• Suitability - Burial: Yes
• Sunlight Resistance: Yes

Plenum/Non-Plenum:
• Plenum (Y/N): No

awg # triads overall cable-
nominal
dia. (mm)
belden cable
part number
Action
16 4 16.256 1097A Request A Quote
16 8 22.149 1098A Request A Quote
16 12 26.594 1099A Request A Quote
16 16 31.344 3118A Request A Quote
16 24 36.424 1100A Request A Quote
16 36 45.034 3130A Request A Quote

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question