Product Details
Belden® paired cable products are manufactured in a variety of gage sizes, dimensions, insulation materials, shielding configurations, and jacketing materials including Plenum and High-Temperature versions to meet the technical requirements of many different types of systems.
Paired cables allow balanced signal transmission, which results in lower crosstalk through common mode rejection. Due to the improved noise immunity of twisted pairs, they generally permit higher data speeds than multi-conductor cables.
Insulation:
• Material: S-R PVC - Semi-Rigid Polyvinyl Chloride
• Wall Thickness (mm): 0.279
Outer Shield Drain Wire AWG:
• AWG: 24
• Stranding: 7x32
• Material: TC - Tinned Copper
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.813
Mechanical Charactertistics (Overall):
• Operating Temperature Range: -30°C To +80°C
• UL Temperature Rating: 80°C (UL AWM Style 2464)
• Bulk Cable Weight: 17.858 Kg/Km
• Max. Recommended Pulling Tension: 48.930 N
• Min. Bend Radius/Minor Axis: 44.450 mm
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMG
• CEC/C(UL) Specification: CMG
• AWM Specification: UL Style 2464 (300 V 80°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: CSA AWM I/II A
Electrical Characteristics (Overall):
• Nom. Inductance (µH/m): 0.62339
• Nom. Capacitance Conductor to Conductor (pF/m): 131.24
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/m): 242.794
• Nominal Velocity of Propagation (VP %): 60
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 78.744
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/km): 59.058
• Max. Operating Voltage - UL: 300 V RMS (UL AWM Style 2464)
• Max. Recommended Current: 2.2 Amps/Conductor @ 25°C
Flame Test:
• UL Flame Test: UL1685 FT4 Loading
• CSA Flame Test: FT4
Plenum/Non-Plenum:
• Plenum (Y/N): No
• Plenum Number: 88641, 82641
awg | # pairs | overall cable- nominal dia. (mm) |
belden cable part number |
Action |
24 | 1 | 3.962 | 9501 | Request A Quote |
24 | 2 | 5.639 | 9502 | Request A Quote |
24 | 3 | 5.893 | 9503 | Request A Quote |
24 | 4 | 6.579 | 9504 | Request A Quote |
24 | 5 | 7.341 | 9505 | Request A Quote |
24 | 6 | 7.341 | 9506 | Request A Quote |
24 | 7 | 7.468 | 9507 | Request A Quote |
24 | 8 | 8.230 | 9508 | Request A Quote |
24 | 9 | 8.484 | 9509 | Request A Quote |
24 | 10 | 9.347 | 9510 | Request A Quote |
24 | 15 | 10.592 | 9515 | Request A Quote |
24 | 19 | 11.379 | 9519 | Request A Quote |
24 | 25 | 12.776 | 9525 | Request A Quote |
24 | 50 | 17.983 | 9550 | Request A Quote |