Belden 9525 Cable 24 AWG 25 Pairs Overall Beldfoil Shield Computer Cables for EIA RS-232 Application Multi Conductor Cable
Select gauge from drop-down menu for prices:
- Belden Cable Overall Beldfoil Shield Computer Cables for EIA RS-232 Application Multi Conductor Paired Cable
- Belden 9501 Cable 24 AWG 1 Pair Overall Beldfoil Shield Computer Cables for EIA RS-232 Application Multi Conductor Cable
- Belden 9502 Cable 24 AWG 2 Pairs Overall Beldfoil Shield Computer Cables for EIA RS-232 Application Multi Conductor Cable
- Belden 9503 Cable 24 AWG 3 Pairs Overall Beldfoil Shield Computer Cables for EIA RS-232 Application Multi Conductor Cable
- Belden 9504 Cable 24 AWG 4 Pairs Overall Beldfoil Shield Computer Cables for EIA RS-232 Application Multi Conductor Cable
- Belden 9505 Cable 24 AWG 5 Pairs Overall Beldfoil Shield Computer Cables for EIA RS-232 Application Multi Conductor Cable
- Belden 9506 Cable 24 AWG 6 Pairs Overall Beldfoil Shield Computer Cables for EIA RS-232 Application Multi Conductor Cable
- Belden 9507 Cable 24 AWG 7 Pairs Overall Beldfoil Shield Computer Cables for EIA RS-232 Application Multi Conductor Cable
- Belden 9508 Cable 24 AWG 8 Pairs Overall Beldfoil Shield Computer Cables for EIA RS-232 Application Multi Conductor Cable
- Belden 9509 Cable 24 AWG 9 Pairs Overall Beldfoil Shield Computer Cables for EIA RS-232 Application Multi Conductor Cable
- Belden 9510 Cable 24 AWG 10 Pairs Overall Beldfoil Shield Computer Cables for EIA RS-232 Application Multi Conductor Cable
- Belden 9515 Cable 24 AWG 15 Pairs Overall Beldfoil Shield Computer Cables for EIA RS-232 Application Multi Conductor Cable
- Belden 9519 Cable 24 AWG 19 Pairs Overall Beldfoil Shield Computer Cables for EIA RS-232 Application Multi Conductor Cable
- Belden 9550 Cable 24 AWG 50 Pairs Overall Beldfoil Shield Computer Cables for EIA RS-232 Application Multi Conductor Cable
Description:
• 24 AWG stranded (7x32) TC conductors, semi-rigid PVC insulation, twisted pairs, overall Beldfoil shield (100% coverage), 24 AWG stranded TC drain Wire (continued), PVC jacket.
Insulation:
• Material: S-R PVC - Semi-Rigid Polyvinyl Chloride
• Wall Thickness (mm): 0.2794
Outer Shield Drain Wire AWG:
• AWG: 24
• Stranding: 7x32
• Material: TC - Tinned Copper
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 1.143
Mechanical Charactertistics (Overall):
• Operating Temperature Range: -30°C To +80°C
• Non-UL Temperature Rating: 80°C (UL AWM Style 2464)
• Bulk Cable Weight: 145 lbs/1000 ft.
• Max. Recommended Pulling Tension: 275 lbs.
• Min. Bend Radius/Minor Axis: 5.250 in.
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMG
• CEC/C(UL) Specification: CMG
• AWM Specification: UL Style 2464 (300 V 80°C)
• CSA Specification: AWM I A
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Electrical Characteristics (Overall):
• Nom. Capacitance Conductor to Conductor (pF/ft): 30
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/ft): 50
• Nominal Velocity of Propagation (VP %): 60
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 24
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 16.5
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 1.1 Amps/Conductor @ 25°C
Flame Test:
• UL Flame Test: UL1685 FT4 Loading
• C(UL) Flame Test: FT4
Plenum/Non-Plenum:
• Plenum (Y/N): No
technical specification: | |
awg | 24 |
# pairs | 25 |
stranding | 7x32 |
no. of conductors | 50 |
conductor material | tinned copper |
outer shield - type | tape |
outer shield - material | aluminum foil-polyester tape w/shorting fold |
overall cable- nominal dia. (mm) | 12.776 |
belden cable part number | 9525 |