Belden 12 AWG CSA Control and Power 600V TC/CIC Multi Conductor UnShielded Cable

Belden 12 AWG CSA Control and Power 600V TC/CIC Multi Conductor UnShielded Cable

Select gauge from drop-down menu for prices:

Belden 12 AWG CSA Control and Power 600V TC/CIC Multi Conductor UnShielded Cable

Product Details

Suitable for use in 300V, 600V or some 1000V environments, Belden offers a complete line of unarmored CSA-rated control, instrumentation and power cables.

Combined with a wide range of conductor, insulation and jacket options, Belden has the right cable solution to fit your needs.

Benefits:
• Eliminates the need for costly conduit or burial piping
• Provides superior mechanical protection for use in underground or hazardous environments
• Resists sunlight, chemicals and oil for long-life performance

Features:
• Designed specifically to meet CSA22.2 Type CIC standard
• Wide range of conductor and pair counts
• Armored options available

Ground Wire:
• Ground Wire (Y/N): Y
• AWG: 14
• Stranding: 7x22
• Conductor Material: BC - Bare Copper
• Insulation Material: XLPE - Cross Linked Polyethylene

Insulation:
• Material: FR-XLPE - Cross Linked Polyethylene

Outer Jacket:
• Material: FR-PVC - Polyvinyl Chloride
• Outer Jacket Ripcord: Yes

Mechanical Charactertistics (Overall):
• Installation Temperature Range: -25°C To +90°C
• Operating Temperature Range: -40°C To +90°C
• Bulk Cable Weight: 94 lbs/1000 ft.
• Max. Recommended Pulling Tension: 174 lbs.
• Min. Bend Radius/Minor Axis: 4.200 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• CSA Specification: C22.2 #230 Type TC; C22.2#239 Type CIC
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 05/24/2006
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 1.60
• Max. Operating Voltage - Non-UL: 600 (CSA TC)

Flame Test:
• CSA Flame Test: FT4

Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes
• Sunlight Resistance: Yes

Plenum/Non-Plenum:
• Plenum (Y/N): No

awg # conductors overall cable-
nominal
dia. (mm)
belden cable
part
number
Action
12 2 10.668 21550 Request A Quote
12 3 11.176 21551 Request A Quote
12 4 12.192 21552 Request A Quote
12 5 - 21553 Request A Quote
12 6 15.494 21554 Request A Quote
12 7 - 21555 Request A Quote
12 8 16.510 21556 Request A Quote
12 9 - 21557 Request A Quote
12 10 19.304 21558 Request A Quote
12 11 - 21559 Request A Quote
12 12 19.812 21560 Request A Quote
12 13 - 21561 Request A Quote
12 14 - 21562 Request A Quote
12 15 22.860 21563 Request A Quote
12 16 - 21564 Request A Quote
12 17 - 21565 Request A Quote
12 18 - 21566 Request A Quote
12 19 - 21567 Request A Quote
12 20 24.384 21568 Request A Quote
12 21 - 21569 Request A Quote
12 22 - 21570 Request A Quote
12 23 - 21571 Request A Quote
12 24 - 21572 Request A Quote
12 25 27.940 21573 Request A Quote
12 26 - 21574 Request A Quote
12 27 - 21575 Request A Quote
12 28 - 21576 Request A Quote
12 29 - 21577 Request A Quote
12 30 - 21578 Request A Quote
12 31 - 21579 Request A Quote
12 32 - 21580 Request A Quote
12 33 - 21581 Request A Quote
12 34 - 21582 Request A Quote
12 35 - 21583 Request A Quote
12 36 - 21584 Request A Quote
12 37 - 21585 Request A Quote
12 38 - 21586 Request A Quote
12 39 - 21587 Request A Quote
12 40 - 21588 Request A Quote
12 41 - 21589 Request A Quote
12 42 - 21590 Request A Quote
12 43 - 21591 Request A Quote
12 44 - 21592 Request A Quote
12 45 - 21593 Request A Quote
12 46 - 21594 Request A Quote
12 47 - 21595 Request A Quote
12 48 - 21596 Request A Quote
12 49 - 21597 Request A Quote
12 50 - 21598 Request A Quote

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.