Prysmian and Draka Cable AICI-I/O/RM/C-W F6 Mud Protected Indoor and Outdoor Flame Retardant Steel wire braiding Fiber Optic Cable

Prysmian and Draka Cable AICI-I/O/RM/C-W F6 Mud Protected Indoor and Outdoor Flame Retardant Steel wire braiding Fiber Optic Cable

Select gauge from drop-down menu for prices:

Prysmian and Draka Cable AICI-I/O/RM/C-W F6 Mud Protected Indoor and Outdoor Flame Retardant Steel wire braiding Fiber Optic Cable

Product Details

Prysmian and Draka Cable AICI-I/O/RM/C-W F6 Mud Protected Indoor and Outdoor Flame Retardant Steel wire braiding Fiber Optic Cable

Optical cable for industrial environments. The cable is suitable for both indoor and outdoor installation. Continiuous submergence in water is not recommended. Outer sheath (1) is made from black UV-stabilized and weather resistant material and may be exposed for shorter periods to fluids such as diesel and mineral oils. The resistance to these fluids is according to IEC60811-2-1. The cable is reinforced with a steel wire braiding between the two sheaths. Strength elements of glass yarn around the cable core allow easy installation of long lengths. The 0.9 mm tight buffer is easy to strip allowing fast and reliable splicing and connector mounting. Each fibre is colour coded for easy identification. The outer sheath is marked to show fibre type and cable type.

An additional outer sheath is added for improved oil- and MUD protection. The outer sheath is DRAK GREY.

Cable Properties:

*Tensile Strength (IEC 60794-1-2E1):
• Max tensile load during installation - See above
• Max tensile load during operation - See above

Crush (IEC 60794-1-2E3): 2000 N/10cm

Imapact (IEC 60794-1-2E4): 1 impacts 25J

Torsion (IEC 60794-1-2E7): ±1 turn/1m

Cable Bending:
• Minimum bending diameter - 15x outer diameter
• Cable bend (IEC 60794-1-2E11) - <0.5 dB/ ± 5 turn
• Flexibility (IEC 60794-1-2E8) - 1000 cycles

Temperature Window:
• Operation - -40°C to +70°C
• Installation - -10°C to +70°C
• Storage - -40°C to +70°C

Water Tightness* (IEC 60794-1-2F5B): < 3 m/24 hours

Fire and Smoke Classifications:
• IEC 61032-1
• IEC 60332-3-22 (Cat. A)
• IEC 60332-3-24 (Cat. C)
• IEC 61034
• IEC 60754-1

Chemical Resistance:
• Mineral oils IRM 902 (IEC60811-2-1) - 7 days/100°C
• Diesel - IRM 903 (IEC60811-2-1) - 7 days/100°C

Weight and Dimensions
Number of fibres Secondary coating Outer Diameter
(mm)
Weight
(kg/km)
Tensile strength*
[Inst//oper.]
[N]
4 0.9 10.2 140 700/250
8 0.9 11.4 165 800/350
12 0.9 12.4 195 1200/500
24 0.9 14.0 240 1700/750

Ordering Information
Number of
fibres
Cable Type Fiber data
sheet
Prysmian and
Draka cable
part number
Action
4 G4-9/125 AICI-I/O/RM/C-W C03e 20116218 Request A Quote
8 G8-9/125 AICI-I/O/RM/CW C03e - Request A Quote
12 G12-9/125 AICI-I/O/RM/C-W C03e - Request A Quote
24 G24-9/125 AICI-I/O/RM/C-W C03e - Request A Quote
4 G4-50/125 AICI-I/O/RM/C-W C23 - Request A Quote
8 G8-50/125 AICI-I/O/RM/C-W C23 - Request A Quote
12 G12-50/125 AICI-I/O/RM/C-W C23 886926 Request A Quote
24 G24-50/125 AICI-I/O/RM/C-W C23 - Request A Quote
4 G4-50/125OM3 AICI-I/O/RM/C-W C31 - Request A Quote
8 G8-50/125OM3 AICI-I/O/RM/C-W C31 - Request A Quote
12 G12-50/125OM3 AICI-I/O/RM/C-W C31 - Request A Quote
24 G24-50/125OM3 AICI-I/O/RM/C-W C31 - Request A Quote
4 G4-62.5/125 AICI-I/O/RM/C-W C02 886701 Request A Quote
8 G8-62.5/125 AICI-I/O/RM/C-W C02 886774 Request A Quote
12 G12-62.5/125 AICI-I/O/RM/C-W C02 - Request A Quote
24 G24-62.5/125 AICI-I/O/RM/C-W C02 - Request A Quote