Helukabel MultiSpeed 600-C-PUR -J/-O Special Cable For Drag Chains 1000V Screened Halogen Free EMC-Preferred Type Meter Marking Cable
Select gauge from drop-down menu for prices:
- Helukabel 10 AWG 1 Core MultiSpeed 600-C-PUR -J/-O Special Cable For Drag Chains 1000V Screened EMC-Preferred Type Meter Marking Cable 25901
- Helukabel 10 AWG 1 Core 6 mm² Cross-Sec. MultiSpeed 600-C-PUR -J/-O Special Cable For Drag Chains 1000V Screened EMC-Preferred Type Cable 25282
- Helukabel 8 AWG 1 Core MultiSpeed 600-C-PUR -J/-O Special Cable For Drag Chains 1000V Screened EMC-Preferred Type Meter Marking Cable 25902
- Helukabel 8 AWG 1 Core 10 mm² Cross-Sec. MultiSpeed 600-C-PUR -J/-O Special Cable For Drag Chains 1000V Screened EMC-Preferred Type Cable 25283
- Helukabel 6 AWG 1 Core MultiSpeed 600-C-PUR -J/-O Special Cable For Drag Chains 1000V Screened EMC-Preferred Type Meter Marking Cable 25903
- Helukabel 6 AWG 1 Core 16 mm² Cross-Sec. MultiSpeed 600-C-PUR -J/-O Special Cable For Drag Chains 1000V Screened EMC-Preferred Type Cable 25284
- Helukabel 4 AWG 1 Core MultiSpeed 600-C-PUR -J/-O Special Cable For Drag Chains 1000V Screened EMC-Preferred Type Meter Marking Cable 25904
- Helukabel 4 AWG 1 Core 25 mm² Cross-Sec. MultiSpeed 600-C-PUR -J/-O Special Cable For Drag Chains 1000V Screened EMC-Preferred Type Cable 25285
- Helukabel 2 AWG 1 Core MultiSpeed 600-C-PUR -J/-O Special Cable For Drag Chains 1000V Screened EMC-Preferred Type Meter Marking Cable 25905
- Helukabel 2 AWG 1 Core 35 mm² Cross-Sec. MultiSpeed 600-C-PUR -J/-O Special Cable For Drag Chains 1000V Screened EMC-Preferred Type Cable 25286
- Helukabel 1 AWG 1 Core MultiSpeed 600-C-PUR -J/-O Special Cable For Drag Chains 1000V Screened EMC-Preferred Type Meter Marking Cable 25906
- Helukabel 1 AWG 1 Core 50 mm² Cross-Sec. MultiSpeed 600-C-PUR -J/-O Special Cable For Drag Chains 1000V Screened EMC-Preferred Type Cable 25287
- Helukabel 2/0 AWG 1 Core MultiSpeed 600-C-PUR -J/-O Special Cable For Drag Chains 1000V Screened EMC-Preferred Type Meter Marking Cable 25907
- Helukabel 2/0 AWG 1 Core 70 mm² Cross-Sec. MultiSpeed 600-C-PUR -J/-O Special Cable For Drag Chains 1000V Screened EMC-Preferred Type Cable 25288
- Helukabel 3/0 AWG 1 Core MultiSpeed 600-C-PUR -J/-O Special Cable For Drag Chains 1000V Screened EMC-Preferred Type Meter Marking Cable 25908
- Helukabel 3/0 AWG 1 Core 95 mm² Cross-Sec. MultiSpeed 600-C-PUR -J/-O Special Cable For Drag Chains 1000V Screened EMC-Preferred Type Cable 25289
- Helukabel 4/0 AWG 1 Core MultiSpeed 600-C-PUR -J/-O Special Cable For Drag Chains 1000V Screened EMC-Preferred Type Meter Marking Cable 25909
- Helukabel 4/0 AWG 1 Core 120 mm² Cross-Sec. MultiSpeed 600-C-PUR -J/-O Special Cable For Drag Chains 1000V Screened EMC-Preferred Type Cable 25290
- Helukabel 250 MCM 1 Core MultiSpeed 600-C-PUR -J/-O Special Cable For Drag Chains 1000V Screened EMC-Preferred Type Meter Marking Cable 25910
- Helukabel 250 MCM 1 Core 150 mm² Cross-Sec. MultiSpeed 600-C-PUR -J/-O Special Cable For Drag Chains 1000V Screened EMC-Preferred Type Cable 25291
- Helukabel 350 MCM 1 Core MultiSpeed 600-C-PUR -J/-O Special Cable For Drag Chains 1000V Screened EMC-Preferred Type Meter Marking Cable 25911
- Helukabel 350 MCM 1 Core 185 mm² Cross-Sec. MultiSpeed 600-C-PUR -J/-O Special Cable For Drag Chains 1000V Screened EMC-Preferred Type Cable 25292
- Helukabel 450 MCM 1 Core MultiSpeed 600-C-PUR -J/-O Special Cable For Drag Chains 1000V Screened EMC-Preferred Type Meter Marking Cable 25912
- Helukabel 450 MCM 1 Core 240 mm² Cross-Sec. MultiSpeed 600-C-PUR -J/-O Special Cable For Drag Chains 1000V Screened EMC-Preferred Type Cable 25293
- Helukabel 550 MCM 1 Core MultiSpeed 600-C-PUR -J/-O Special Cable For Drag Chains 1000V Screened EMC-Preferred Type Meter Marking Cable 25913
- Helukabel 550 MCM 1 Core 300 mm² Cross-Sec. MultiSpeed 600-C-PUR -J/-O Special Cable For Drag Chains 1000V Screened EMC-Preferred Type Cable 25294
Product Details
Technical Data:
• Special drag chain core line for extreme mechanical stresses adapted to DIN VDE 0285-525-2-31/DIN EN 50525-2-31 and UL style 10553
Temperature Range:
• flexing -30°C to +80°C
• fixed installation -40°C to +80°C
Nominal Voltage:
• VDE U0/U 600/1000 V
• UL/CSA 1000 V
Test Voltage: 3000 V
Insulation Resistance:
• min. 100 MOhm x km
Minimum Bending Radius:
• flexing 5x core Ø
• fixed installation 3x core Ø
Cable Structure:
• Bare copper conductor, ultra-fine wire to DIN VDE 0295 cl.6, column 4, BS 6360 cl.6 and/or IEC 60228 cl.6
• Core insulation of thermoplastic polymer in either black or green/yellow
• Braided screen of tinned Cu wires, coverage approx. 85%
• Core wrapping with fleece
• Outer sheath of special polyurethane, TMPU adapted to DIN VDE 0207-363-10-2 / DIN EN 50363-10-2
• Sheath colour black (RAL 9005)
• With meter marking
Properties:
• Flame retardant, UL VW-1, CSA FT1
• Halogen-free
• Abrasion resistant
• Very good oil resistance
• Very good alternating bending strength
• Very high resistance to mechanical stresses
• Higher notch resistance
• Ozone and UV-resistant
• Coolant resistant
• The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers
Note:
• G = with green-yellow conductor x = without green-yellow conductor (OZ)
• Please observe applicable installation regulations for use in energy supply chains.
• AWG sizes are approximate equivalent values. The actual cross-section is in mm².
• Unscreened analogue type: MULTISPEED® 600-C-PUR-J/O
Application:
• These special drag chain core cables permit extended use with extreme requirements, with free movement, without tensile stresses or forced movements. Suitable for installation in long traverse paths and high speeds in dry, high temperature influence in dry, moist and wet environments and in the open air. These cables can be used for all applications demanding the highest requirements in flexibility, abrasion resistance, ozone and chemical resistance. For applications extending beyond standard solutions (e. g. composting plants or high-lift conveyor systems working at extremely low speeds), we recommend that you request our questionnaire, which has been especially designed for energy supply systems. Before installation in cable trays please read the instructions.
• EMC = Electromagnetic compatibility
• To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
• = The product is conformed with the EC Low-Voltage Directive 2006/95/EC.