Belden 16 AWG CSA Instrumentation 600V ACIC Armored Individually and Overall Beldfoil Shielded Triads 7x24 Cable
Select gauge from drop-down menu for prices:
- Belden 24501 16 AWG 1 Triad 600V ACIC Armored Aluminum Cable
- Belden 24507 16 AWG 2 Triads 600V ACIC Armored Aluminum Cable
- Belden 24508 16 AWG 4 Triads 600V ACIC Armored Aluminum Cable
- Belden 24509 16 AWG 8 Triads 600V ACIC Armored Aluminum Cable
- Belden 25502 16 AWG 1 Triad 600V ACIC Armored Steel Cable
- Belden 25507 16 AWG 2 Triads 600V ACIC Armored Steel Cable
- Belden 25509 16 AWG 4 Triads 600V ACIC Armored Steel Cable
- Belden 25508 16 AWG 8 Triads 600V ACIC Armored Steel Cable
Product Details
Suitable for use in 300V, 600V or some 1000V environments, Belden offers a complete line of unarmored CSA-rated control, instrumentation and power cables.
Combined with a wide range of conductor, insulation and jacket options, Belden has the right cable solution to fit your needs.
Benefits:
• Eliminates the need for costly conduit or burial piping
• Provides superior mechanical protection for use in underground or hazardous environments
• Resists sunlight, chemicals and oil for long-life performance
Features:
• Designed specifically to meet CSA22.2 Type CIC standard
• Wide range of conductor and pair counts
• Armored options available
Separator:
• Separator Material: Polyester
Insulation:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness (mm): 0.762
Inner Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Dia. (mm): 9.144
Outer Shield Drain Wire AWG:
• AWG: 18
• Stranding: 7x26
• Material: TC - Tinned Copper
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Dia. (mm): 16.764
• Outer Jacket Ripcord: Yes
Armor:
• Armor Type: Interlocked
• Armor Material: Aluminum
Mechanical Charactertistics (Overall):
• Installation Temperature Range: -25°C To +105°C
• Wet Temperature Range: -40°C To +75°C
• Dry Temperature Range: -40°C To +105°C
• Bulk Cable Weight: 195 lbs/1000 ft.
• Max. Recommended Pulling Tension: 130 lbs.
• Min. Bend Radius/Minor Axis: 7.900 in.
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• CSA Specification: C22.2#239, Type ACIC, C22.2#174, HLBCD, C22.2#0.3, Clause 4.31 Low Acid Test
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2006
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: Low Acid Test
Electrical Characteristics (Overall):
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 3.8
• Max. Operating Voltage - Other: 600 (CEC ACIC)
Flame Test:
• CSA Flame Test: FT4
Plenum/Non-Plenum:
• Plenum (Y/N): No
awg | # triads | belden cable part number |
Action | ||
al. | steel | aluminum | steel | ||
16 | 16 | 1 | 24501 | 25502 | Request A Quote |
16 | 16 | 2 | 24507 | 25507 | Request A Quote |
16 | 16 | 4 | 24508 | 25509 | Request A Quote |
16 | 16 | 8 | 24509 | 25508 | Request A Quote |