Belden 8 AWG CSA Control and Power 1000V TC/CIC Multi Conductor UnShielded Cable
Select gauge from drop-down menu for prices:
Product Details
Suitable for use in 300V, 600V or some 1000V environments, Belden offers a complete line of unarmored CSA-rated control, instrumentation and power cables.
Combined with a wide range of conductor, insulation and jacket options, Belden has the right cable solution to fit your needs.
Benefits:
• Eliminates the need for costly conduit or burial piping
• Provides superior mechanical protection for use in underground or hazardous environments
• Resists sunlight, chemicals and oil for long-life performance
Features:
• Designed specifically to meet CSA22.2 Type CIC standard
• Wide range of conductor and pair counts
• Armored options available
Ground Wire:
• Ground Wire (Y/N): Y
• AWG: 10
• Stranding: 7x18
• Conductor Material: BC - Bare Copper
• Insulation Material: XLPE - Cross Linked Polyethylene
Insulation:
• Material: FR-XLPE - Cross Linked Polyethylene
Outer Jacket:
• Material: FR-PVC - Polyvinyl Chloride
• Outer Jacket Ripcord: Yes
Usage (Overall):
Suitable Applications:
• Analog signal transmission; factory floor; cable trays
Mechanical Charactertistics (Overall):
• Installation Temperature Range: -25°C To +90°C
• Operating Temperature Range: -40°C To +90°C
• Non-UL Temperature Rating: 90°C
• Bulk Cable Weight: 366.097 Kg/Km
• Max. Recommended Pulling Tension: 1183.221 N
• Min. Bend Radius/Minor Axis: 154.940 mm
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• CSA Specification: C22.2 #230 Type TC, C22.2 #38 1000V RW90
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 05/24/2006
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Electrical Characteristics (Overall):
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 2.100
• Max. Operating Voltage - Non-UL: 600 (CSA TC)
Flame Test:
• CSA Flame Test: FT4
Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes
• Suitability - Burial: Yes
• Sunlight Resistance: Yes
Plenum/Non-Plenum:
• Plenum (Y/N): No
awg | # conductors | overall cable- nominal dia. (mm) |
belden cable part number |
Action |
8 | 2 | 15.519 | 21450 | Request A Quote |
8 | 3 | 16.408 | 21451 | Request A Quote |
8 | 4 | - | 21452 | Request A Quote |