Amercable Type PV Photovoltaic Cable Single Conductor 2kV 90C RHH/RHW-2 CSA 1kV RPV-90 UL4703 37-711
Select gauge from drop-down menu for prices:
- Amercable Type 14/19 AWG PV Photovoltaic Cable Single Conductor 2kV 90C RHH/RHW-2 CSA 1kV RPV-90 UL4703 37-711-201
- Amercable Type 12/19 AWG PV Photovoltaic Cable Single Conductor 2kV 90C RHH/RHW-2 CSA 1kV RPV-90 UL4703 37-711-202
- Amercable Type 10/37 AWG PV Photovoltaic Cable Single Conductor 2kV 90C RHH/RHW-2 CSA 1kV RPV-90 UL4703 37-711-203
- Amercable Type 8/37 AWG PV Photovoltaic Cable Single Conductor 2kV 90C RHH/RHW-2 CSA 1kV RPV-90 UL4703 37-711-204
- Amercable Type 14/7 AWG PV Photovoltaic Cable Single Conductor 2kV 90C RHH/RHW-2 CSA 1kV RPV-90 UL4703 37-711-101
- Amercable Type 12/7 AWG PV Photovoltaic Cable Single Conductor 2kV 90C RHH/RHW-2 CSA 1kV RPV-90 UL4703 37-711-102
- Amercable Type 10/7 AWG PV Photovoltaic Cable Single Conductor 2kV 90C RHH/RHW-2 CSA 1kV RPV-90 UL4703 37-711-103
- Amercable Type 8/7 AWG PV Photovoltaic Cable Single Conductor 2kV 90C RHH/RHW-2 CSA 1kV RPV-90 UL4703 37-711-104
Conductor: Soft annealed stranded copper per ASTM B-3
Insulation: Extruded thermosetting Ethylene Propylene Rubber (EPR) meeting UL 44 and UL 4703
Jacket: Black, flame retardant, oil, abrasion, chemical and sunlight resistant chlorinated polyethylene (CPE) meeting UL 44 and UL 4703
Applications:
Nexans AmerCable’s Type PV is a single-conductor cable that meets the newest standards as introduced in National Electrical Code (NEC) Article 690.
Applications include connection to module junction boxes; required cable routing in balance of system (BOS) integration; and where also allowed by
the NEC.
Features:
• A two layer construction of flame retardant, oil and sunlight resistant Chlorinated Polyethylene (CPE) over an Ethylene-Propylene Rubber (EPR) inner layer. This design is based on a construction allowed for use on ungrounded systems as described in NEC Article 690 without the need for conduit when installed exposed.
• Provides superior protection from ozone weather and abrasion than other single layer constructions while maintaining flexibility for ease of installation
• Suitable for continuous operating temperature of 90°C wet or dry
• Direct burial 2kV
• Cold bend and impact: -40°C
• UL listed as Sunlight Resistant
• Flame Resistance: UL VW-1
• Compatible with all major connectors
Ratings & Approvals:
• UL listed as 2000V Type PV (E322538)
• UL listed as RHH/RHW-2 (E76087)
• CSA listed as RPV-90 (LL80350)
• 90°C Temperature Rating
• UL Standard 44/CSA C22.2 No. 38: Thermoset Insulated Wires & Cables, Types RHH, RHW-2, UL VW-1
• UL Subject 4703: Outline of Investigation for Photovoltaic Wire,Type PV, Direct Burial
• CSA Standard C22.2 No 271: Photovoltaic Cables, RPV-90
• ASTM B-3: Standard Specification for Soft or Annealed Copper Wire
• ASTM B-8: Standard Specification for Concentric Lay Stranded Copper Conductors, Hard, Medium-Hard or Soft (Class B strand only)
• ASTM B-33: Standard Specification for Tinned Soft or Annealed Copper Wire for Electrical Purposes (Flexible strand only)
• ASTM B-172: Standard Specification for Rope-Lay Stranded Copper Conductors having Bunch-Stranded Members, for Electrical Conductors (Flexible strand only)
• RoHS compliant
size(awg) | number of wires | ampacity 90° c | amercable part number | Action |
Type PV – Flexible Tinned Copper | ||||
14 | 19 | 35 | 37-711-201 | Request a Quote |
12 | 19 | 40 | 37-711-202 | Request a Quote |
10 | 37 | 55 | 37-711-203 | Request a Quote |
8 | 37 | 80 | 37-711-204 | Request a Quote |
size(awg) | number of wires | ampacity 90° c | amercable part number | Action |
Type PV – Class B Bare Copper | ||||
14 | 7 | 35 | 37-711-101 | Request a Quote |
12 | 7 | 40 | 37-711-102 | Request a Quote |
10 | 7 | 55 | 37-711-103 | Request a Quote |
8 | 7 | 80 | 37-711-104 | Request a Quote |