Belden Cable Combination Overall Beldfoil Shield Audio Control and Instrumentation Multi Conductor Paired Cable
Select gauge from drop-down menu for prices:
- Belden 8732 Cable 22 AWG 2 Pairs Combination Braid Shield Audio Control and Instrumentation 7x30 Stranded PVC Jacket Cable
- Belden 8437 Cable 22 AWG 1 Pair Overall Braid Shield Audio Control and Instrumentation Solid TC PVC Jacket Cable
- Belden 8441 Cable 22 AWG 1 Pair Overall Braid Shield Audio Control and Instrumentation Stranded 7x30 TC PVC Jacket Cable
- Belden 8208 Cable 18 AWG 1 Pair Overall Braid Shield Audio Control and Instrumentation Stranded 16x30 TC PVC Jacket Cable
Product Details
Belden® paired cable products are manufactured in a variety of gage sizes, dimensions, insulation materials, shielding configurations, and jacketing materials including Plenum and High-Temperature versions to meet the technical requirements of many different types of systems.
Paired cables allow balanced signal transmission, which results in lower crosstalk through common mode rejection. Due to the improved noise immunity of twisted pairs, they generally permit higher data speeds than multi-conductor cables.
Insulation:
• Material: PE - Polyethylene
• Wall Thickness (mm): 0.533
Inner Shield:
• Type: Braid
• Material: TC - Tinned Copper
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.762
Mechanical Charactertistics (Overall):
• Operating Temperature Range: -20°C To +60°C
• UL Temperature Rating: 60°C (UL AWM Style 2094)
• Bulk Cable Weight: 55.063 Kg/Km
• Max. Recommended Pulling Tension: 262.444 N
• Min. Bend Radius/Minor Axis: 57.150 mm
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CM
• CEC/C(UL) Specification: CM
• AWM Specification: UL Style 2094 (300 V 60°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 74 (Shielded pair)
• Nom. Capacitance Conductor to Conductor (pF/m): 37 (Shielded pair only)
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/m): 68.901
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 50.5274
• Maximum Conductor DC Resistance @ 20°C (Ohm/100 m): 10.8
• Max. Operating Voltage - UL: 300 V RMS (UL AWM Style 2094)
• Max. Recommended Current: 2.3 Amps/Conductor @ 25°C
Flame Test:
• UL Flame Test: UL1685 UL Loading
Plenum/Non-Plenum:
• Plenum (Y/N): No
awg | # pairs | overall cable- nominal dia. (mm) |
belden cable part number |
Action |
22 | 2 | 5.232 x 8.433 | 8732 | Request A Quote |
22 | 1 | 4.775 | 8437 | Request A Quote |
22 | 1 | 4.928 | 8441 | Request A Quote |
18 | 1 | 6.528 | 8208 | Request A Quote |