General Cable Teck90® 2C XLPE PVC AIA PVC Control and Power Armored 1000 V CSA

General Cable Teck90® 2C XLPE PVC AIA PVC Control and Power Armored 1000 V CSA

Select gauge from drop-down menu for prices:

General Cable Teck90® 2C XLPE PVC AIA PVC Control and Power Armored 1000 V CSA

Product Details

Conductor:
• 14 AWG thru 8 AWG bare copper Class B compressed concentric round to ASTM B8
• 6 AWG thru 1000 kcmil bare copper compact Class B strand

Insulation:
• Cross-linked Polyethylene (XLPE), Type RW90
• Color-coded: 14 AWG to 2 AWG—black and white; 1 AWG to 1000 kcmil—printed numbers

Ground (Bonding) Conductor: The conductor consists of one uninsulated stranded bare copper conductor

Inner Jacket: Lead-free, flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black

Armor: Aluminum Interlocked Armor (AIA)

Overall Jacket: Lead-free, ACID-FLAME-CHECK ??® flameretardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black

Options: Galvanized Steel Interlocked Armor (GSIA)

Applications:
• For exposed and concealed wiring in dry, damp or wet locations
• For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
• For direct earth burial (with protection as required by inspection authority)
• For wiring in all hazardous locations when used with certified HL cable glands

Features:
• Rated at 90?C wet or dry
• Excellent crush, oil and chemical resistance
• Provides long service life
• Meets cold bend and impact tests at -40?C

Compliances:
Industry Compliances: CSA Standard C22.2 No. 131 and No. 174

Flame Test Compliances:
• CSA FT1 and FT4
• IEEE 383 (70,000 BTU/hr)
• UL 1581 (70,000 BTU/hr)
• IEEE 1202 (70,000 BTU/hr) CSA FT4
• ICEA T-30-520 (70,000 BTU/hr)

Other Compliances:
• Hazardous Location Rating: HL
• EPA 40 CFR, Part 261 for leachable lead content per TCLP method
• OSHA Acceptable
• RoHS Compliant

Packaging:
• For Canadian customers, lengths are provided on returnable wood or steel reels that require a deposit. Extra charges apply for lagging, pulling eyes, paralleling and plexing
• For U.S. customers, material cut to length and shipped on non-returnable wood reels, while lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit. Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing

cond.
size
(AWG/
kcmil)
no.
of
cond.
ampacity**
(30?
cambient)
general
cable
part
number
Action
14 2 25 794520* Request A Quote
12 2 30 308550* Request A Quote
10 2 40 793140* Request A Quote
8 2 55 331260* Request A Quote
6 2 75 11206.332083* Request A Quote
4 2 95 11288.040400* Request A Quote
3 2 115 11288.220300* Request A Quote
2 2 130 11288.040200* Request A Quote
1 2 145 11288.020100* Request A Quote
1/0 2 170 11288.045100* Request A Quote
2/0 2 195 11288.045200* Request A Quote
3/0 2 225 11288.045300* Request A Quote
4/0 2 260 11288.145400* Request A Quote
250 2 290 11288.226000* Request A Quote
350 2 350 11288.226200* Request A Quote
500 2 430 11288.226500* Request A Quote
750 2 535 11288.227000* Request A Quote
1000 2 615 11288.227500* Request A Quote