Prysmian and Draka Cable AeroLink 3/16 Figure 8 Self Supporting Cables
Select gauge from drop-down menu for prices:
Product Details
Features and Benefits:
Integral Stranded, Galvanized Steel Messenger:
• Self-supporting design requires no overlashing, allowing installation in a single pass
• Standard 3/16" galvanized strand
• Web, jacket and strand dimensions sized for standard hardware
Dry Water-Blocking Technology:
• Permits rapid cable preparation and termination
• Water-blocking materials are easily removed
Flexible Buffer Tubes:
• Superior kink resistance and increased flexibility
• Facilitates route management in closures
• Eliminates need for closure transportation tubes
Medium Density Polyethylene Jacket:
• Low friction installation
• Excellent protection from environmental hazards
Sheath Markings:
• Provide positive identification and length verification
• Custom print available
Reverse Oscillated Lay Stranding Method: Facilitates mid-span access of fibers
Performance: Meets or exceeds the performance requirements of Telcordia GR-20 & ICEA 640, and is tested in accordance with relevant EIA-455 series FOTPs for fiber optic cables
Registered Supplier: ISO 9001, ISO 14001, TL 9000, and OHSAS 18001
fiber count | buffer tube count |
max. fiber/ tube |
buffer tube od | cable dimensions | cable weight | |||
(mm) | (inches) | (mm) | (inches) | (kg/km) | (lb/kft) | |||
2-60 | 5 | 12 | 2.5 | 0.098 | 10.5 x 19.5 | 0.41 x 0.77 | 218 | 147 |
62-72 | 6 | 12 | 2.5 | 0.098 | 11.3 x 20.3 | 0.45 x 0.80 | 233 | 157 |
74-96 | 8 | 12 | 2.5 | 0.098 | 13.0 x 22.0 | 0.51 x 0.87 | 262 | 176 |
98-144 | 12 | 12 | 2.5 | 0.098 | 16.3 x 25.3 | 0.64 x 1.00 | 331 | 223 |
performance specifications | ||
bend radius dynamic static |
20 x cable od 10 x cable od |
|
tensile rating Cable Installation w/o Messenger Cable Residual w/o Messenger |
n 2,700 800 |
lbf 600 180 |
Span Rating (1% installed sag) NESC Light Load District NESC Medium Load District NESC Heavy Load District |
m 161 137 84 |
ft 530 450 310 |
crush resistance short/ long term |
n/cm 220/110 |
lbf/in 125/63 |
temperature ratings operation installation storage/shipping |
*c -40 to +70 -30 to +60 -40 to +75 |
°f -40 to +158 -22 to +140 -40 to +167 |