Belden Cable UnShielded Audio Control and Instrumentation Multi Conductor Solid Paired Cable

Belden Cable UnShielded Audio Control and Instrumentation Multi Conductor Solid Paired Cable

Product Details

Belden® paired cable products are manufactured in a variety of gage sizes, dimensions, insulation materials, shielding configurations, and jacketing materials including Plenum and High-Temperature versions to meet the technical requirements of many different types of systems.

Paired cables allow balanced signal transmission, which results in lower crosstalk through common mode rejection. Due to the improved noise immunity of twisted pairs, they generally permit higher data speeds than multi-conductor cables.

Insulation:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness (mm): 0.254

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.8128

Mechanical Charactertistics (Overall):
• Operating Temperature Range: -20°C To +80°C
• UL Temperature Rating: 80°C (UL AWM Style 2576)
• Bulk Cable Weight: 26.788 Kg/Km
• Max. Recommended Pulling Tension: 88.964 N
• Min. Bend Radius/Minor Axis: 50.800 mm

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMG
• CEC/C(UL) Specification: CMG
• AWM Specification: UL Style 2576 (150 V 80°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Capacitance Conductor to Conductor (pF/m): 72.182
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 80.0564
• Max. Operating Voltage - UL: 300 V RMS (CMG)
• Max. Operating Voltage - UL: 150 V RMS (UL AWM Style 2576)
• Max. Recommended Current: 1.6 Amps/Conductor @ 25°C

Flame Test:
• UL Flame Test: UL1685 FT4 Loading
• CSA Flame Test: FT4

Suitability:
• Sunlight Resistance: Yes

Plenum/Non-Plenum:
• Plenum (Y/N): No

awg # pairs overall cable-
nominal
dia. (mm)
belden cable
part
number
Action
24 2 5.055 9562 Request A Quote
24 6 7.341 9566 Request A Quote
24 10 7.874 9570 Request A Quote
24 25 12.182 9585 Request A Quote
22 1 3.962 8740 Request A Quote
22 2 5.842 8741 Request A Quote
22 3 6.147 8742 Request A Quote
22 4 6.706 8757 Request A Quote
22 6 7.442 8743 Request A Quote
22 8 8.204 9160 Request A Quote
22 9 8.890 8744 Request A Quote
19 1 4.623 8486 Request A Quote