General Cable Genspeed® 6 Category 6 Outside Plant Cable Standards-Compliant
Select gauge from drop-down menu for prices:
Product Details
It comes with a flooding compound that is a waterproof gel closely covering the separating cross-web that holds the copper conductors. This cable features polyolefin insulation and polyethylene jacket. Insulation and jacketing of this cable improves its protective aspects from either chemical or mechanical damages that it may get subjected to in the environment. GenSpeed Cat 6 outside Plant Cable is approved worthy of its intended purpose after meeting the following specifications:
1.ANSI/TIA 568-C.2 and ANSI/TIA 862
2.UL 444
3.ICEA S-116-732
4.ICEA S-102-700
5.ISO/IEC 11801
Features and benefits
The innovative cross-web separating layer creates a convenient maximum pair separation, thus enhancing the electrical performance of this cable. Gel-filled flooding compound is waterproof to prevent moisture from getting into contact with copper conductors in underground and wet installation applications. This cable has TRU-Mark print containing footage markings that will help you make your counts hence preventing further confusions that may occur. Interested in a cable with wide temperature range? Make GenSpeed Cat 6 outside Plant Cable your cable of choice since it can withstand extreme weather conditions.
Bare copper conductors are insulated with polyolefin compound, which is semi-conducting hence ensuring your safety when handling the cable. Polyethylene jacketing offers a great protection against harsh sunlight radiations as well as preventing the cable from mechanical damages such as abrasions. All these attributes improves the service life of this cable and I would recommend that you go for it and enjoy a long term service.
Applications
GenSpeed Cat 6 outside Plant Cable is intended to serve in the applications of digital video, ATMs, Token Ring, CDDI, broadband and baseband analog videos. This cable is installed through ducts and conduit systems only.
nominal cable diameter (in) | 0.250 |
nominal cable weight (lbs/1000 ft) | 32 |
minimum bend radius (in) | 1.0 |
maximum pulling force (lbs) | 32 |
temperature rating (?c) installation: operation: |
-30 to +60 -45 to +80 |
jacket color |
reel |
black | 7136100 |
frequency mhz |
psacr* (min) |
acr*
(min)
|
insertion loss (max) |
PSNEXT (min) |
next (min) |
psacrf (min) |
acrf (min) |
return loss (min) |
1 | 70.3 | 72.3 | 2.0 | 72.3 | 74.3 | 64.8 | 67.8 | 20.0 |
4 | 59.3 | 61.5 | 3.8 | 63.3 | 65.3 | 52.8 | 55.7 | 23.0 |
10 | 51.3 | 53.3 | 6.0 | 57.3 | 59.3 | 44.8 | 47.8 | 25.0 |
16 | 46.7 | 48.7 | 7.6 | 54.2 | 56.2 | 40.7 | 43.7 | 25.0 |
20 | 44.3 | 46.3 | 8.5 | 52.8 | 54.8 | 38.8 | 41.7 | 25.0 |
31.25 | 39.2 | 41.2 | 10.7 | 49.9 | 51.9 | 34.9 | 37.9 | 23.6 |
62.5 | 29.9 | 32.0 | 15.4 | 45.4 | 47.4 | 28.9 | 31.8 | 21.5 |
100 | 22.5 | 24.5 | 19.8 | 42.3 | 44.3 | 24.8 | 27.8 | 20.1 |
200 | 22.5 | 10.8 | 29.0 | 37.8 | 39.8 | 18.8 | 21.8 | 18.0 |
250 | 3.5 | 5.5 | 32.8 | 36.3 | 38.3 | 16.8 | 19.8 | 17.3 |
dc resistance (max) ohms/100 m (328 ft) @ 20?c |
9.38 |
dc resistance unbalance (max) individual pair % |
4.00 |
delay skew (max) ns/100 m |
45 |
nom. velocity of propagation % speed of light |
69 |
characteristic impedance frequency (f): 1-250 mhz |
ohms
100 ± 15
|