Belden 20 AWG CSA Instrumentation 300V ACIC Armored Individually and Overall Beldfoil Shielded Triads 7x28 Cable

Belden 20 AWG CSA Instrumentation 300V ACIC Armored Individually and Overall Beldfoil Shielded Triads 7x28 Cable

Product Details

Suitable for use in 300V, 600V or some 1000V environments, Belden offers a complete line of unarmored CSA-rated control, instrumentation and power cables.

Combined with a wide range of conductor, insulation and jacket options, Belden has the right cable solution to fit your needs.

Benefits:
• Eliminates the need for costly conduit or burial piping
• Provides superior mechanical protection for use in underground or hazardous environments
• Resists sunlight, chemicals and oil for long-life performance

Features:
• Designed specifically to meet CSA22.2 Type CIC standard
• Wide range of conductor and pair counts
• Armored options available

Insulation:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness (mm): 0.508

Inner Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Dia. (mm): 6.858

Outer Shield Drain Wire AWG:
• AWG: 22
• Stranding: 7x30
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Outer Jacket Ripcord: Yes
• Outer Jacket over Armor (y/n): Y

Armor:
• Armor Type: Interlocked
• Armor Material: Aluminum

Mechanical Charactertistics (Overall):
• Installation Temperature Range: -25°C To +105°C
• Wet Temperature Range: -40°C To +75°C
• Dry Temperature Range: -40°C To +105°C
• Non-UL Temperature Rating: 105°C
• Bulk Cable Weight: 206.860 Kg/Km
• Max. Recommended Pulling Tension: 151.239 N
• Min. Bend Radius/Minor Axis: 173.990 mm

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• CSA Specification: C22.2#239, Type ACIC, C22.2#174, HLBCD, C22.2#0.3, Clause 4.31 Low Acid Test
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2006
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Max. Operating Voltage - Non-UL: 300 (CSA ACIC)

Flame Test:
• C(UL) Flame Test: FT4

Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes

Plenum/Non-Plenum:
• Plenum (Y/N): No

awg # triads belden cable
part number
Action
al. steel aluminum steel
20 20 1 23545 26539 Request A Quote
20 20 2 23546 26540 Request A Quote
20 20 4 23547 26541 Request A Quote
20 20 8 23548 26542 Request A Quote
20 20 12 23571 26553 Request A Quote
20 20 16 23549 26543 Request A Quote
20 20 24 23550 26544 Request A Quote

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question