Belden Cable Blue Hose 9463 Cable

Belden Cable Blue Hose 9463 Cable

Min Length:

Precio habitual $2.55 $1.90 Oferta /per Foot

Product Details

Leading the way for Data Highway applications, Belden Blue Hose (9463) cables provide the robust interface needed for connecting programmable logic control (PLC) processors, I/O devices and other devices on the factory floor.

Insulation:
• Material: PE - Polyethylene
• Diameter (in.): 0.078

Outer Jacket Drain Wire AWG:
• AWG: 20
• Stranding: 7x28H
• Drain Wire Conductor Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride

Mechanical Characteristics (Overall):
• Operating Temperature Range: -40°C To +80°C
• UL Temperature Rating: 80°C (UL AWM Style 2464)
• Bulk Cable Weight: 36 lbs/1000 ft.
• Max. Recommended Pulling Tension: 48 lbs.
• Min. Bend Radius/Minor Axis: 2.400 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CL2, CM
• CEC/C(UL) Specification: CM
• AWM Specification: UL Style 2464 (300 V 80°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• PMSHA Specification: P-7K-SC-182141
• Customer Part Number Reference Specification: Allen Bradley P/N 1770-CD

Electrical Characteristics (Overall):
• Nom. Charactertistic Impedance: (ohm): 78
• Nom. Inductance (µH/ft): 0.12
• Nom. Capacitance Conductor to Conductor (pF/ft): 19.7
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/ft): 36
• Nominal Velocity of Propagation: VP (%): 66
• Nominal Delay (ns/ft): 1.54
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 9.5
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 4.1
• Max. Operating Voltage - UL: 300 V RMS (UL AWM Style 2464)
• Max. Operating Voltage - UL: 300 V RMS (NEC Type CM)
• Max. Operating Voltage - UL: 300 V RMS (NEC Type CL2)

Flame Test:
• UL Flame Test: UL 1685 UL Loading

Suitability:
• Sunlight Resistance: Yes

Plenum/Non-Plenum:
• Plenum Number: 89463

Benefits:
• Reliable, durable performance
• Application flexibililty
• Immediate, real-time data

Features:
• Robust interface
• Wide variety of Blue Hose constructions
• Peer-to-Peer messaging

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question