Belden 18 AWG CSA Instrumentation 300V ACIC Armored Individually and Overall Beldfoil Shielded Pairs 7x26 Cable

Belden 18 AWG CSA Instrumentation 300V ACIC Armored Individually and Overall Beldfoil Shielded Pairs 7x26 Cable

Product Details

Suitable for use in 300V, 600V or some 1000V environments, Belden offers a complete line of unarmored CSA-rated control, instrumentation and power cables.

Combined with a wide range of conductor, insulation and jacket options, Belden has the right cable solution to fit your needs.

Benefits:
• Eliminates the need for costly conduit or burial piping
• Provides superior mechanical protection for use in underground or hazardous environments
• Resists sunlight, chemicals and oil for long-life performance

Features:
• Designed specifically to meet CSA22.2 Type CIC standard
• Wide range of conductor and pair counts
• Armored options available

Insulation:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness (mm): 0.635

Inner Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Dia. (mm): 7.62

Outer Shield Drain Wire AWG:
• AWG: 20
• Stranding: 7x28
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Outer Jacket Ripcord: Yes
• Outer Jacket over Armor (y/n): Y

Armor:
• Armor Type: Interlocked
• Armor Material: Aluminum
• Diameter over Armor: 0.50

Mechanical Charactertistics (Overall):
• Installation Temperature Range: -25°C To +105°C
• Wet Temperature Range: -40°C To +75°C
• Dry Temperature Range: -40°C To +105°C
• Non-UL Temperature Rating: 105°C
• Bulk Cable Weight: 238.112 Kg/Km
• Max. Recommended Pulling Tension: 253.547 N
• Min. Bend Radius/Minor Axis: 182.880 mm

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• CEC/C(UL) Specification: ACIC
• CSA Specification: C22.2#239, Type ACIC, C22.2#174, HLABCD, C22.2#0.3, Clause 4.31 Low Acid Test
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2006
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 22.3108 
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/km): 32.81         
• Max. Operating Voltage - Other: 300 (CEC ACIC)

Flame Test:
• C(UL) Flame Test: FT4

Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes

Plenum/Non-Plenum:
• Plenum (Y/N): No

awg # pairs belden cable
part number
Action
al. steel aluminum steel
18 18 1 23533 26514 Request A Quote
18 18 2 23511 26515 Request A Quote
18 18 4 23530 26516 Request A Quote
18 18 6 23528 26517 Request A Quote
18 18 8 23531 26518 Request A Quote
18 18 12 23524 26519 Request A Quote
18 18 16 23519 26520 Request A Quote
18 18 24 23542 26521 Request A Quote
18 18 36 23554 26555 Request A Quote