Belden Cable High Temperature Control and Instrumentation Multi Conductor Overall Beldfoil Shield Cable
Select gauge from drop-down menu for prices:
- Belden 83394 Cable 22 AWG 2 Conductors Control and Instrumentation Multi Conductor Overall Beldfoil Shield Cable
- Belden 83395 Cable 22 AWG 3 Conductors Control and Instrumentation Multi Conductor Overall Beldfoil Shield Cable
- Belden 83396 Cable 22 AWG 4 Conductors Control and Instrumentation Multi Conductor Overall Beldfoil Shield Cable
- Belden 83393 Cable 20 AWG 2 Conductors Control and Instrumentation Multi Conductor Overall Beldfoil Shield Cable
- Belden 85230 Cable 20 AWG 2 Conductors Control and Instrumentation Multi Conductor Overall Beldfoil Shield Tefzel Jacket Cable
- Belden 85240 Cable 20 AWG 3 Conductors Control and Instrumentation Multi Conductor Overall Beldfoil Shield Tefzel Jacket Cable
- Belden 85231 Cable 16 AWG 2 Conductors Control and Instrumentation Multi Conductor Overall Beldfoil Shield Tefzel Jacket Cable
- Belden 85241 Cable 16 AWG 3 Conductors Control and Instrumentation Multi Conductor Overall Beldfoil Shield Tefzel Jacket Cable
Product Details
Description:
• 22 AWG stranded (7x30) TC conductors, conductors cabled, 22 AWG (7x30) stranded TC drain wire, FEP insulation, special Beldfoil® shield (100% coverage), silicone rubber jacket, noise reducing tape.
Insulation:
• Material: FEP - Fluorinated Ethylene Propylene
• Wall Thickness (mm): 0.406
Outer Shield Drain Wire AWG:
• AWG: 22
• Stranding: 7x30
• Material: TC - Tinned Copper
Outer Jacket:
• Material: Silicone Rubber
• Nom. Wall Thickness (mm): 0.762
Mechanical Charactertistics (Overall):
• Operating Temperature Range: -70°C To +150°C
• Bulk Cable Weight: 38.693 Kg/Km
• Max. Recommended Pulling Tension: 120.101 N
• Min. Bend Radius/Minor Axis: 50.800 mm
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• AWM Specification: UL Style 4516 (600 V 150°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: NEMA HP3
Electrical Characteristics (Overall):
• Nom. Inductance (µH/m): 0.6562
• Nom. Capacitance Conductor to Conductor (pF/m): 72.182
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/m): 131.24
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 57.4175
• Max. Operating Voltage - Non-UL: 350 V RMS (Between Conductors)
• Max. Operating Voltage - Non-UL: 2000 V DC (Through Jacket)
• Max. Recommended Current: 2.8 Amps/Conductor @ 25°C
Plenum/Non-Plenum:
• Plenum (Y/N): No
awg | # conductors | overall cable- nominal dia. (mm) |
belden cable part number |
Action |
22 | 2 | 5.055 | 83394 | Request A Quote |
22 | 3 | 5.283 | 83395 | Request A Quote |
22 | 4 | 5.512 | 83396 | Request A Quote |
20 | 2 | 6.147 | 83393 | Request A Quote |
20 | 2 | 4.623 | 85230 | Request A Quote |
20 | 3 | 4.902 | 85240 | Request A Quote |
16 | 2 | 5.334 | 85231 | Request A Quote |
16 | 3 | 5.715 | 85241 | Request A Quote |