Belden 83393 Cable 20 AWG 2 Conductors Control and Instrumentation Multi Conductor Overall Beldfoil Shield Cable

Belden 83393 Cable 20 AWG 2 Conductors Control and Instrumentation Multi Conductor Overall Beldfoil Shield Cable

Belden 83393 Cable 20 AWG 2 Conductors Control and Instrumentation Multi Conductor Overall Beldfoil Shield Cable

Description:
• 20 AWG stranded (7x28) TC conductors, twisted pair, 20 AWG (7x28) stranded TC drain wire, FEP insulation, special Beldfoil® shield (100% coverage), silicone rubber jacket, noise reducing tape.

Insulation:
• Material: FEP - Fluorinated Ethylene Propylene
• Wall Thickness (mm): 0.508

Outer Shield Drain Wire AWG:
• AWG: 20
• Stranding: 7x28
• Material: TC - Tinned Copper

Outer Jacket:
• Material: Silicone Rubber
• Nom. Wall Thickness (mm): 0.9398

Overall Cable:
• Fillers: Fiberglass yarn

Overall Cabling Lay Length and Direction:
• Length (mm): 41.275
• Twists (twist/m): 24.279 (Left Hand Direction)

Mechanical Charactertistics (Overall):
• Operating Temperature Range: -70°C To +150°C
• Bulk Cable Weight: 53.575 Kg/Km
• Max. Recommended Pulling Tension: 112.095 N
• Min. Bend Radius/Minor Axis: 63.500 mm

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• AWM Specification: UL Style 4516 (600 V 150°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: NEMA HP3

Electrical Characteristics (Overall):
• Nom. Inductance (μH/m): 0.6562
• Nom. Capacitance Conductor to Conductor (pF/m): 72.182
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/m): 131.24
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 34.4505
• Max. Operating Voltage - UL: 600 V RMS (UL AWM 4516)
• Max. Operating Voltage - Other: 2000 V DC (Shield to ground through jacket)
• Max. Recommended Current: 3.8 Amps/Conductor @ 25°C ambient (10C Temp. Rise)

Flame Test:
• UL Flame Test: VW-1 (Singles)

Suitability:
• Suitability - Indoor: Yes

Plenum/Non-Plenum:
• Plenum (Y/N): No

technical specification:
awg 20
# conductors 2
stranding 7x28
no. of conductors 2
conductor material tinned copper
outer shield - type tape
outer shield - material aluminum foil-polyester tape
overall cable- nominal dia. (mm) 6.147
belden cable part number 83393