Belden 2 AWG CSA Control and Power 1000V TC/CIC Multi Conductor UnShielded Cable

Belden 2 AWG CSA Control and Power 1000V TC/CIC Multi Conductor UnShielded Cable

Select gauge from drop-down menu for prices:

Product Details

Suitable for use in 300V, 600V or some 1000V environments, Belden offers a complete line of unarmored CSA-rated control, instrumentation and power cables.

Combined with a wide range of conductor, insulation and jacket options, Belden has the right cable solution to fit your needs.

Benefits:
• Eliminates the need for costly conduit or burial piping
• Provides superior mechanical protection for use in underground or hazardous environments
• Resists sunlight, chemicals and oil for long-life performance

Features:
• Designed specifically to meet CSA22.2 Type CIC standard
• Wide range of conductor and pair counts
• Armored options available

Ground Wire:
• Ground Wire (Y/N): Y
• AWG: 6
• Stranding: 7x14
• Conductor Material: BC - Bare Copper
• Insulation Material: XLPE - Cross Linked Polyethylene

Insulation:
• Material: FR-XLPE - Cross Linked Polyethylene

Outer Jacket:
• Material: FR-PVC - Polyvinyl Chloride
• Outer Jacket Ripcord: Yes

Overall Cable:
• Overall Cabling Fillers: Yes

Usage (Overall):
Suitable Applications:
• Analog signal transmission; factory floor; cable trays

Mechanical Charactertistics (Overall):
• Installation Temperature Range: -25°C To +90°C
• Operating Temperature Range: -40°C To +90°C
• Bulk Cable Weight: 1003 lbs/1000 ft.
• Max. Recommended Pulling Tension: 1593 lbs.
• Min. Bend Radius/Minor Axis: 10.500 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• CSA Specification: C22.2 #230 Type TC, C22.2 #38 1000V RW90
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 05/24/2006
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 0.160
• Max. Operating Voltage - Non-UL: 1000 (CSA TC)

Flame Test:
• CSA Flame Test: FT4

Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes
• Suitability - Burial: Yes
• Sunlight Resistance: Yes

Plenum/Non-Plenum:
• Plenum (Y/N): No

awg # conductors overall cable-
nominal
dia. (mm)
belden cable
part
number
Action
2 2 - 21462 Request A Quote
2 3 28.194 21463 Request A Quote
2 4 - 21464 Request A Quote

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question