Ir directamente a la información del producto
1 de 1

Belden CSA Control 600V TECK 90 Composite Armored Unshielded Cable

Belden CSA Control 600V TECK 90 Composite Armored Unshielded Cable

SKU: SKU:  

Length: FT
Enter footage in the box - Cut to one length. Min 1 ft - Max 10000 ft.
Agotado
Los gastos de envío se calculan en la pantalla de pago.
Shipping Available
Free shipping on orders above $1000. *Wires and cables only.
Ver todos los detalles
Product Information

Product Details

Suitable for use in 300V, 600V or some 1000V environments, Belden offers a complete line of unarmored CSA-rated control, instrumentation and power cables.

Combined with a wide range of conductor, insulation and jacket options, Belden has the right cable solution to fit your needs.

Benefits:
• Eliminates the need for costly conduit or burial piping
• Provides superior mechanical protection for use in underground or hazardous environments
• Resists sunlight, chemicals and oil for long-life performance

Features:
• Designed specifically to meet CSA22.2 Type CIC standard
• Wide range of conductor and pair counts
• Armored options available

Ground Wire:
• Ground Wire (Y/N): Y
• Ground Wire AWG: 14
• Ground Wire Stranding: 7x22
• Conductor Material: BC - Bare Copper

Insulation:
• Material: XLPE - Cross Linked Polyethylene
• Nom. Wall Thickness (mm): 0.787

Inner Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Dia. (mm): 14.224

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Dia. (mm): 22.606

Armor:
• Armor Type: Interlocked
• Armor Material: Aluminum
• Diameter over Armor: 0.750

Mechanical Charactertistics (Overall):
• Operating Temperature Range: -40°C To +90°C
• Wet Temperature Range: -40°C To +90°C
• Dry Temperature Range: -40°C To +90°C
• Bulk Cable Weight: 369 lbs/1000 ft.
• Max. Recommended Pulling Tension: 424 lbs.
• Min. Bend Radius/Minor Axis: 8.400 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• CSA Specification: CSA C22.2#131; Hazardous Locations CSA C22.2#0.3 Clause 4.31 Low Acid Gas
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2006
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 2.5 (14 AWG)
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 1.65 (12 AWG)
• Max. Recommended Current: 12 Amps/Conductor @ 25°C (14 AWG)
• Max. Recommended Current: 16 Amps/Conductor @ 25°C (12 AWG)

Flame Test:
• CSA Flame Test: FT4

Suitability:
• Sunlight Resistance: Yes

Plenum/Non-Plenum:
• Plenum (Y/N): No

awg # conductors overall cable-
nominal dia. (mm)
belden cable
part number
Action
14 and 12 6 22.606 6054 Request A Quote
14 and 10 6 - 6051 Request A Quote
14 and 8 6 24.917 6059 Request A Quote
14 and 6 6 29.464 6060 Request A Quote