Belden Cable Category 6A Cable

Belden Cable Category 6A Cable

Select gauge from drop-down menu for prices:

Belden Cable Category 6A Cable

Product Details

Description:
• Category 6A Enhanced (625MHz), 4-Bonded-Pair, Plenum-CMP, Premise Horizontal Cable, 23 AWG Solid Bare Copper Conductors, FEP Insulation, Patented EquiSpline™ & EquiBlock™ Technologies, Ripcord, Flamarrest® Jacket

Insulation:
• Material: FEP - Fluorinated Ethylene Propylene

Separator:
• Separator Material: Patented EquiSpline Central Member

Outer Jacket:
• Tramde Name: Flamarrest (R)
• Material: LS-PVC - Low Smoke Polyvinyl Chloride
• Outer Jacket Ripcord: Yes

Usage (Overall):
Applications:
• Premise Horizontal Cable, 10 Gigabit Ethernet, Wireless, Wi-Fi, 100Base TX, 100Base VG ANYLAN, 155ATM, 622ATM, NTSC/PAL Component or Composite Video, AES/EBU Digital Audio AES51, RS-422, Noisy Environments, PoE, PoE Plus.

Mechanical Characteristics (Overall):
• Storage Temperature Range: -20°C To +75°C
• Installation Temperature Range: +5°C To +50°C
• Operating Temperature Range: -20°C To +75°C
• UL Temperature Rating: 105°C
• Bulk Cable Weight: 39 lbs/1000 ft.
• Max. Recommended Pulling Tension: 40 lbs.
• Min. Bend Radius/Minor Axis: 1.100 in.
• Min. Bend/Installation: 2.500 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMP
• NEC Articles: 800
• CEC/C(UL) Specification: CMP
• EU Directive 2011/65/EU (ROHS II): Yes
• Other Standards: ISO/IEC 11801 ed 2 Amendment 2:2010 Class EA
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 12/31/2015
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Telecommunications Standards: Category 6A - TIA 568.C.2
• ANSI Specification: ANSI/TIA 568-C.2 Category 6A

Electrical Characteristics (Overall):
• Nom. Mutual Capacitance (pF/ft): 17.000
• Maximum Capacitance Unbalance (pF/100m): 90
• Nominal Velocity of Propagation: VP (%): 69.000
• Maximum Delay (ns/100 m): 537.000
• Typical Delay Skew (ns/ft): 30.000
• Max. Delay Skew (ns/100 m): 45.000
• Maximum Conductor DC Resistance @ 20°C (Ohm/100 ft): 7.500
• Max. Operating Voltage - UL: 300 V RMS
• Maximum DCR Unbalanced @ 20°C (%): 3.000 (Conductor-to-Conductor)
• Maximum DCR Unbalanced @ 20°C (%): 5.000 (Pair-to-Pair)

Flame Test:
• UL Flame Test: NFPA 262 Plenum Flame Test (UL910)(FT6)
• C/(UL) Flame Test: FT6
• CSA Flame Test: FT6

Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: No
• Suitability - Buiral: No
• Sunlight Resistance: No
• Oil Resistance: No
• Non-halogenated: No

Plenum/Non-Plenum:
• Plenum(Y/N): Yes
• Plenum Number: 10GXS33 / 10GXS13 (nonbonded)
• Non-Plenum Number: 10GXS32 / 10GXS12 (nonbonded)

QUESTIONS & ANSWERS