Belden OSP6AU Cable 23 AWG 4 Pairs Category 6A Outside Plant Multi Conductor Solid Bare Copper Polyolefin Jacket Cable

Belden OSP6AU Cable 23 AWG 4 Pairs Category 6A Outside Plant Multi Conductor Solid Bare Copper Polyolefin Jacket Cable

Select gauge from drop-down menu for prices:

Belden OSP6AU Cable 23 AWG 4 Pairs Category 6A Outside Plant Multi Conductor Solid Bare Copper Polyolefin Jacket Cable
Belden OSP6AU Cable 23 AWG 4 Pairs Category 6A Outside Plant Multi Conductor Solid Bare Copper Polyolefin Jacket Cable

Description:
• Category 6A (500MHz), 4-Unbonded-Pair, Outside Plant Cable, 23 AWG Solid Bare Copper Conductors, PO Insulation, Patented X-spline Technology, Gel Flooded, Inner Polyolefin Jacket, EquiBlock Barrier Tape, Ripcord, Outer Polyolefin Jacket..

Insulation:
• Material: PO - Polyolefin

Separator:
• Separator Material: Patented X-spline Central Member

Inner Jacket:
• Material: Black PO - Polyolefin
• Nom. Wall Thickness (in.): 0.020
• Nom. Diameter (in.): 0.270
• Inner Jacket Ripcord: No

Outer Jacket:
• Material: Black PO - Polyolefin
• Nom. Diameter (in.): 0.360
• Outer Jacket Ripcord: Yes

Usage (Overall):
Applications:
• Premise Horizontal Cable, 10 Gigabit Ethernet, Wireless, Wi-Fi, 100Base TX, 100Base VG ANYLAN, 155ATM, 622ATM, HDBASET, 4K, NTSC/PAL Component or Composite Video, AES/EBU Digital Audio AES51, RS-422, PoE, PoE Plus

Mechanical Characteristics (Overall):
• Storage Temperature Range: -40°C To +75°C
• Installation Temperature Range: -40°C To +60°C
• Operating Temperature Range: -40°C To +75°C
• UL Tempeature Rating: 60°C
• Bulk Cable Weight: 46.500 lbs/1000 ft.
• Max. Recommended Pulling Tension: 40 lbs.
• Min. Bend/Installation: 3.600 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• EU Directive 2011/65/EU (ROHS II): Yes
• Other Standards: ISO/IEC 11801 ed 2 Amendment 2:2010 Class EA
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 11/15/2016
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Telecommunications Standards: Category 6A - TIA 568.C.2
• ANSI Specification: ANSI/ICEA S-99-689, ANSI/ICEA S-107-704 Paragraph 8.2.1 Water Penetration & ANSI/ICEA S-56-434

Electrical Characteristics (Overall):
• Nom. Mutual Capacitance (pF/ft): 17.000
• Maximum Capacitance Unbalance (pF/100 m): 90
• Nominal Velocity of Propagation: VP (%): 65.000
• Maximum Delay (ns/100 m): 537.000
• Typical Delay Skew (ns/ft): 30.000
• Max. Delay Skew (ns/100 m): 45.000
• Maximum Conductor DC Resistance @ 20°C (Ohm/100 ft): 7.900
• Max. Operating Voltage - UL: 300 V RMS
• Maximum DCR Unbalanced @ 20°C (%): 3.000 (Conductor-to-Conductor)
• Maximum DCR Unbalanced @ 20°C (%): 5.000 (Pair-to-Pair)

Suitability:
• Suitability - Indoor: No
• Suitability - Outdoor: Yes
• Suitability - Aerial: Yes - When supported by messenger wire
• Suitability - Buiral: Yes
• Suitability - Hazardous Locations: No
• Sunlight Resistance: Yes
• Oil Resistance: No
• Non-halogenated: No

Plenum/Non-Plenum:
• Plenum (Y/N): No
• Non-Plenum Number: OSP6AU

technical specification:
awg 23
# pairs 4
stranding solid
no. of conductors 8
conductor material bare copper
outer shield - type -
outer shield - material -
overall cable - nominal diameter (in.) -
belden cable part number OSP6AU