Belden 10GX12 Cable 23 AWG 4 Pairs Category 6A NonBonded-Pair Enhanced Multi Conductor Solid Bare Copper PVC Jacket Cable

Belden 10GX12 Cable 23 AWG 4 Pairs Category 6A NonBonded-Pair Enhanced Multi Conductor Solid Bare Copper PVC Jacket Cable

Select gauge from drop-down menu for prices:

Belden 10GX12 Cable 23 AWG 4 Pairs Category 6A NonBonded-Pair Enhanced Multi Conductor Solid Bare Copper PVC Jacket Cable

Precio habitual $1,215.00 $810.00 Oferta /per Foot

Belden 10GX12 Cable 23 AWG 4 Pairs Category 6A NonBonded-Pair Enhanced Multi Conductor Solid Bare Copper PVC Jacket Cable

Description:
• CAT6A (625MHz), 4-Pair, U/UTP-Unshielded, Riser-CMR, Premise Horizontal Cable, 23 AWG Solid Bare Copper Conductors, Polyolefin Insulation, Patented Double-H spline, Ripcord, PVC Jacket.

Insulation:
• Material: PO - Polyolefin

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Outer Jacket Ripcord: Yes

Usage (Overall):
Applications:
• Premise Horizontal Cable, 10 Gigabit Ethernet, 100BaseTX, 100BaseVG ANYLAN, 155ATM, 622ATM, NTSC/PAL Component or Composite Video, AES/EBU Digital Audio, AES51, RS-422, Noisy Environments, PoE, PoE+.

Mechanical Characteristics (Overall):
• Storage Temperature Range: -20°C To +75°C
• Installation Temperature Range: +5°C To +50°C
• Operating Temperature Range: -20°C To +75°C
• UL Temperature Rating: 90°C
• Bulk Cable Weight: 35 lbs/1000 ft.
• Max. Recommended Pulling Tension: 40 lbs.
• Min. Bend Radius/Minor Axis: 1.200 in.
• Min. Bend/Installation: 3 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMR
• CEC/C(UL) Specification: CMR
• EU Directive 2011/65/EU (ROHS II): Yes
• Other Standards: ISO/IEC 11801 ed 2.1 (2008) Class EA
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Telecommunications Standards: Category 6A - TIA 568.C.2

Electrical Characteristics (Overall):
• Nom. Mutual Capacitance (pF/ft): 17.000
• Maximum Capacitance Unbalance (pF/100m): 50
• Nominal Velocity of Propagation: VP (%): 64.000
• Maximum Delay (ns/100 m): 537 @ 100MHz
• Typical Delay Skew (ns/ft): 35.000
• Max. Delay Skew (ns/100 m): 45
• Maximum Conductor DC Resistance @ 20°C (Ohm/100 ft): 7.400
• Max. Operating Voltage - UL: 300 V RMS
• Maximum DCR Unbalanced @ 20°C (%): 3.000

Flame Test:
• UL Flame Test: UL1666 Riser
• C/(UL) Flame Test: FT4
• CSA Flame Test: FT4
• IEEE Flame Test: 1202

Suitability:
• Suitability - Outdoor: No

Plenum/Non-Plenum:
• Plenum (Y/N): Yes
• Plenum Number: 10GX13

technical specification:
awg 23
# pairs 4
stranding solid
no. of conductors 8
conductor material bare copper
outer shield - type -
outer shield - material -
overall cable - nominal diameter (in.) 0.295
belden cable part number 10GX12

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question