Prysmian Cable 28kV 133% Copper TRXLPE URD CSA Medium Voltage Utility Cables

Prysmian Cable 28kV 133% Copper TRXLPE URD CSA Medium Voltage Utility Cables

Select gauge from drop-down menu for prices:

Prysmian Cable 28kV 133% Copper TRXLPE URD CSA Medium Voltage Utility Cables

Product Details

Conductor: Solid or Class B compact or compressed concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.

Conductor Shield: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.

Insulation: Natural high dielectric strength VOLTENE™ TRXLPE insulation, exhibiting an optimum balance of mechanical and electrical properties, insuring resistance to treeing.

Insulation Shield: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.

Metallic Shield: Solid bare copper wires, helically applied and uniformly spaced.

Jacket: Black insulating sunlight resistant linear low density polyethylene encapsulating the neutral wires with three extruded red stripes.

Description: Single conductor cable with aluminum or copper conductors, triple extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength VOLTALENE™ TRXLPE insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, black encapsulating linear low-density polyethylene (LLDPE) jacket.

Options:
• Black LLDPE jacket with no stripes
• Black PVC jacket sleeved over separator tape
• No Jacket
• EPROTENAX™ (EPR) insulation
• Multiplex cables
• Tinned round and flat strap neutrals
• Strandseal®
• Super smooth conductor shield
• Cables made to AEIC CS8 and/or ICEA S-94-649
• 46kV

Installations:
• Conduit in Air
• Direct Buried
• Underground Duct
• Isolated in Air
• Wet Locations
• Dry Locations
• With Messenger
• Utility Primary

Specifications and Ratings:
• CSA - CSA C68.5 -40°C
• For 90°C continuous, 130°C emergency, 250°C short-circuit operation.

conductor insulation
thickness
(mils)
concentric
neutral
cond.
dia.(in)
ins.
dia.
(in)
ins.
shield
diameter (in)
jacket
dia.(in)
cable
weight
(lbs/kft)
min.
bending
radius (in)

amp.
(amps)
+/- sequence
imp.
resistance
(µΩ/ft)
+/- sequence
imp.
reactance
(µΩ/ft)

amp.
(amps)
+/- sequence
imp.
resistance
(µΩ/ft)
+/- sequence
imp.
reactance
(µΩ/ft)
prysmian
cable
part
number
(a) (b) (c) (d) 90°c in duct 90°c direct buried
28kv 133% copper single phase - full neutral
1/0 solid cu 345 16-#12 8.26 27.41 29.74 36.69 1863 305 211 0.84 0.11 277 0.84 0.11 QB701ZC
1/0 awg cu 345 16-#12 8.59 27.64 29.97 36.92 1879 305 211 0.85 0.11 276 0.85 0.11 QB801ZC
2/0 awg cu 345 20-#12 9.60 28.65 30.99 37.94 2160 305 240 0.68 0.10 314 0.68 0.10 QB901ZC
3/0 awg cu 345 26-#12 10.82 29.87 32.21 39.16 2538 330 276 0.53 0.10 359 0.53 0.10 QBA01ZC
4/0 awg cu 345 32-#12 12.14 31.19 33.53 40.48 2962 330 312 0.42 0.09 407 0.42 0.09 QBB01ZC
28kv 133% copper three phase - one-third neutral
1/0 solid cu 345 14-#16 8.26 27.41 29.74 35.17 1486 305 213 0.41 0.17 280 0.45 0.32 QB700ZC
1/0 awg cu 345 14-#16 8.59 27.64 29.97 35.40 1502 305 212 0.42 0.17 278 0.46 0.32 QB800ZC
2/0 awg cu 345 17-#16 9.60 28.65 30.99 36.41 1701 305 240 0.34 0.16 312 0.38 0.30 QB900ZC
3/0 awg cu 345 21-#16 10.82 29.87 32.21 37.63 1951 305 273 0.27 0.16 347 0.32 0.29 QBA00ZC
4/0 awg cu 345 27-#16 12.14 31.19 33.53 38.95 2269 330 309 0.22 0.15 382 0.27 0.28 QBB00ZC
250 MCM cu 345 21-#14 13.28 32.59 34.93 41.03 2638 330 338 0.19 0.15 407 0.25 0.26 QBC00ZC
350 MCM cu 345 28-#14 15.72 35.03 37.36 44.89 3405 381 402 0.14 0.14 458 0.21 0.23 QBD00ZC
500 MCM cu 345 26-#12 18.77 38.07 40.41 48.78 4530 406 473 0.11 0.13 502 0.18 0.19 QBE00ZC
750 MCM cu 345 25-#10 24.59 44.15 47.35 56.79 6561 457 557 0.08 0.12 568 0.15 0.15 QBF00XC
1000 MCM cu 345 32-#10 28.37 47.93 51.13 60.58 8226 508 609 0.07 0.11 620 0.13 0.12 QBG00XC

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.