Teck 90 Armoured Power Shielded Single Conductor 90 MIL 100%/133% 5kV
Select gauge from drop-down menu for prices:
Teck 90 Armoured Power Shielded Single Conductor 90 MIL 100%/133% 5kV
- Teck 90 Armoured Power Shielded Single Conductor 90 MIL 100%/133% 5kV - AWG Size Cond 6
- Teck 90 Armoured Power Shielded Single Conductor 90 MIL 100%/133% 5kV - AWG Size Cond 4
- Teck 90 Armoured Power Shielded Single Conductor 90 MIL 100%/133% 5kV - AWG Size Cond 2
- Teck 90 Armoured Power Shielded Single Conductor 90 MIL 100%/133% 5kV - AWG Size Cond 1
- Teck 90 Armoured Power Shielded Single Conductor 90 MIL 100%/133% 5kV - AWG Size Cond 1/0
- Teck 90 Armoured Power Shielded Single Conductor 90 MIL 100%/133% 5kV - AWG Size Cond 2/0
- Teck 90 Armoured Power Shielded Single Conductor 90 MIL 100%/133% 5kV - AWG Size Cond 3/0
- Teck 90 Armoured Power Shielded Single Conductor 90 MIL 100%/133% 5kV - AWG Size Cond 4/0
- Teck 90 Armoured Power Shielded Single Conductor 90 MIL 100%/133% 5kV - AWG Size Cond 250
- Teck 90 Armoured Power Shielded Single Conductor 90 MIL 100%/133% 5kV - AWG Size Cond 350
- Teck 90 Armoured Power Shielded Single Conductor 90 MIL 100%/133% 5kV - AWG Size Cond 500
- Teck 90 Armoured Power Shielded Single Conductor 90 MIL 100%/133% 5kV - AWG Size Cond 750
- Teck 90 Armoured Power Shielded Single Conductor 90 MIL 100%/133% 5kV - AWG Size Cond 1000
Teck 90 Armoured Power Shielded Single Conductor 90 MIL 100%/133% 5kV
Specifications:
- Teck 90 Armoured Power
- Shielded Single Conductor
- 90 MIL 100%/133% 5kV
- TR-XLPE/PVC/AIA/PVC
- CSA FT1 & FT4
- CSA C22.2 No. 131 & 174
- CSA C68.3
- IEEE 383 & 1202 (70,000 BTU/hr) Flame Test
- ICEA T-29-520 (210,000 BTU/hr) Vertical Flame Test
- ICEA T-30-520 (70,000 BTU/hr) Vertical Flame Test
CONSTRUCTION:
- Conductor: Bare copper Class B compact or compressed stranded
- Conductor Shield: Extruded thermoset semi-conducting shield
- Insulation: Tree-Retardant Cross-Linked Polyethylene (TR-XLPE)
- Insulation Shield: Extruded thermosetting semi-conducting shield
- Ground (Bonding) Conductor: Stranded bare copper conductor
- Inner Jacket: Flame-retardant and moisture resistant Polyvinyl Chloride (PVC)
- Armour: Aluminum Interlocked Armour (AIA)
- Outer Jacket: Low-temperature, moisture and sunlight resistant Polyvinyl Chloride (PVC), orange
- Options: Other coloured outer jacket and constructions available upon request
Size AWG - Condition | Size AWG - Bond Wire |
Amp (30 Degree C Ambient) | Catalog Number | Action |
6 | 8 | 112 | 19002-02-060 | Request A Quote |
4 | 6 | 148 | 19002-03-060 | Request A Quote |
2 | 6 | 195 | 19002-04-060 | Request A Quote |
1 | 4 | 225 | 19002-05-060 | Request A Quote |
1/0 | 4 | 260 | 19002-06-060 | Request A Quote |
2/0 | 4 | 299 | 19002-07-060 | Request A Quote |
3/0 | 3 | 345 | 19002-08-060 | Request A Quote |
4/0 | 3 | 400 | 19002-09-060 | Request A Quote |
250 | 2 | 444 | 19002-10-060 | Request A Quote |
350 | 1 | 549 | 19002-12-060 | Request A Quote |
500 | 1/0 | 688 | 19002-14-060 | Request A Quote |
750 | 2/0 | 889 | 19002-16-060 | Request A Quote |
1000 | 2/0 | 1061 | 19002-17-060 | Request A Quote |