Belden 14 AWG CSA Control 600V CIC Multi Conductor 7x22 UnShielded Cable

Belden 14 AWG CSA Control 600V CIC Multi Conductor 7x22 UnShielded Cable

Product Details

Suitable for use in 300V, 600V or some 1000V environments, Belden offers a complete line of unarmored CSA-rated control, instrumentation and power cables.

Combined with a wide range of conductor, insulation and jacket options, Belden has the right cable solution to fit your needs.

Benefits:
• Eliminates the need for costly conduit or burial piping
• Provides superior mechanical protection for use in underground or hazardous environments
• Resists sunlight, chemicals and oil for long-life performance

Features:
• Designed specifically to meet CSA22.2 Type CIC standard
• Wide range of conductor and pair counts
• Armored options available

Insulation:
• Material: XLPE - Cross Linked Polyethylene
• Wall Thickness (mm): 0.762

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 1.143
• Outer Jacket Ripcord: Yes

Mechanical Charactertistics (Overall):
• Installation Temperature Range: -25°C To +90°C
• Operating Temperature Range: -40°C To +90°C
• Non-UL Temperature Rating: 90°C
• Bulk Cable Weight: 62 lbs/1000 ft.
• Min. Bend Radius/Minor Axis: 3.700 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• CSA Specification: C22.2#131, Type CIC, C22.2#0.3, Clause 4.31 Low Acid Test
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2006
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 2.6
• Max. Operating Voltage - Non-UL: 300 (CSA TC)

Flame Test:
• CSA Flame Test: FT4

Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes
• Sunlight Resistance: Yes

Plenum/Non-Plenum:
• Plenum (Y/N): No

awg # conductors overall cable-
nominal
dia. (mm)
belden cable
part
number
Action
14 2 9.322 22100 Request A Quote
14 3 9.855 22101 Request A Quote
14 4 10.744 22102 Request A Quote
14 5 11.735 22103 Request A Quote
14 6 12.802 22104 Request A Quote
14 7 12.802 22105 Request A Quote
14 8 14.630 22106 Request A Quote
14 9 15.697 22107 Request A Quote
14 10 16.993 22108 Request A Quote
14 12 17.501 22110 Request A Quote
14 16 19.406 22114 Request A Quote
14 20 22.504 22118 Request A Quote

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question