Lapp OLFLEX® CHAIN 90 P Black Single Conductor Unshielded Flexible Cable
Select gauge from drop-down menu for prices:
- Lapp 1026514 16 AWG 1C OLFLEX CHAIN 90 P Black Unshielded Flexible Cable
- Lapp 1026516 14 AWG 1C OLFLEX CHAIN 90 P Black Unshielded Flexible Cable
- Lapp 1026518 12 AWG 1C OLFLEX CHAIN 90 P Black Unshielded Flexible Cable
- Lapp 1026520 10 AWG 1C OLFLEX CHAIN 90 P Black Unshielded Flexible Cable
- Lapp 1026522 8 AWG 1C OLFLEX CHAIN 90 P Black Unshielded Flexible Cable
- Lapp 1026524 6 AWG 1C OLFLEX CHAIN 90 P Black Unshielded Flexible Cable
- Lapp 1026526 4 AWG 1C OLFLEX CHAIN 90 P Black Unshielded Flexible Cable
- Lapp 1026528 2 AWG 1C OLFLEX CHAIN 90 P Black Unshielded Flexible Cable
- Lapp 1026530 1 AWG 1C OLFLEX CHAIN 90 P Black Unshielded Flexible Cable
- Lapp 1026532 2/0 AWG 1C OLFLEX CHAIN 90 P Black Unshielded Flexible Cable
- Lapp 1026534 3/0 AWG 1C OLFLEX CHAIN 90 P Black Unshielded Flexible Cable
- Lapp 1026536 4/0 AWG 1C OLFLEX CHAIN 90 P Black Unshielded Flexible Cable
- Lapp 1026538 250MCM 1C OLFLEX CHAIN 90 P Black Unshielded Flexible Cable
- Lapp 1026540 350MCM 1C OLFLEX CHAIN 90 P Black Unshielded Flexible Cable
- Lapp 1026542 450MCM 1C OLFLEX CHAIN 90 P Black Unshielded Flexible Cable
- Lapp 1026544 500MCM 1C OLFLEX CHAIN 90 P Black Unshielded Flexible Cable
ÖLFLEX® CHAIN 90 P is a highly flexible PUR 1000V single conductor black unshielded cable for continuous flex applications. The polyurethane jacket is mechanically and chemically resistant to many environments.
Construction
Conductors
• Finely stranded bare copper
Insulation
• Special black or green/yellow compound based on TPE
Jacket
• Polyurethane; black
Technical Data
Minimum Bend Radius:
• for installation: 3 x cable diameter
• for continuous flexing: 7.5 x cable diameter
Temperature Range:
• for continuous flexing: -35°C to +80°C
• for flexible use: -50°C to +80°C
Nominal Voltage:
• UL/CSA: 1000V
• IEC U0/U: 600/1000V
Test Voltage:
• 4000V
Conductor Stranding:
• Class 6 super fine wire
Standards:
• CE, RoHS
Features:
• Suitable for heavy duty power chain applications
• Can substitute multi-conductor power cables where space requirements can cause problems
• Suitable for dry or damp interior use
• Available in larger conductor sizes for power applications
• CSA FT1 flame retardant
AWG | No. of Conductors (incl. ground) |
Nominal Outer Diameter |
Copper Weight (lbs/mft) |
Approx. Weight (lbs/mft) |
Part Number | |
inches | mm | |||||
16 AWG (1.5 mm2) | ||||||
16 | 1 | 0.248 | 6.3 | 10 | 32 | 1026514 |
14 AWG (2.5 mm2) | ||||||
14 | 1 | 0.272 | 6.9 | 16 | 42 | 1026516 |
12 AWG (4 mm2) | ||||||
12 | 1 | 0.283 | 7.2 | 26 | 52 | 1026518 |
10 AWG (6 mm2) | ||||||
10 | 1 | 0.303 | 7.7 | 39 | 64 | 1026520 |
8 AWG (10 mm2) | ||||||
8 | 1 | 0.358 | 9.1 | 65 | 98 | 1026522 |
6 AWG (16 mm2) | ||||||
6 | 1 | 0.417 | 10.6 | 103 | 138 | 1026524 |
4 AWG (25 mm2) | ||||||
4 | 1 | 0.484 | 12.3 | 161 | 195 | 1026526 |
2 AWG (35 mm2) | ||||||
2 | 1 | 0.524 | 13.3 | 226 | 278 | 1026528 |
1 AWG (50 mm2) | ||||||
1 | 1 | 0.626 | 15.9 | 323 | 360 | 1026530 |
2/0 AWG (70 mm2) | ||||||
2/0 | 1 | 0.709 | 18 | 452 | 522 | 1026532 |
3/0 AWG (95 mm2) | ||||||
3/0 | 1 | 0.783 | 19.9 | 614 | 672 | 1026534 |
4/0 AWG (120 mm2) | ||||||
4/0 | 1 | 0.886 | 22.5 | 775 | 840 | 1026536 |
250MCM (150 mm2) | ||||||
250MCM | 1 | 0.969 | 24.6 | 969 | 1000 | 1026538 |
350MCM (185 mm2) | ||||||
350MCM | 1 | 1.071 | 27.2 | 1195 | 1203 | 1026540 |
450MCM (240 mm2) | ||||||
450MCM | 1 | 1.264 | 32.1 | 1550 | 1602 | 1026542 |
500MCM (300 mm2) | ||||||