15KV UL Type MV-105, MC-HL, CT Shielded, EPR Insulation 133%, Aluminum Copper
Select gauge from drop-down menu for prices:
- 15KV UL Type MV-105, MC-HL, CT Shielded, EPR - HW311 00203
- 15KV UL Type MV-105, MC-HL, CT Shielded, EPR - HW311 00103
- 15KV UL Type MV-105, MC-HL, CT Shielded, EPR - HW311 10103
- 15KV UL Type MV-105, MC-HL, CT Shielded, EPR - HW311 20103
- 15KV UL Type MV-105, MC-HL, CT Shielded, EPR - HW311 40103
- 15KV UL Type MV-105, MC-HL, CT Shielded, EPR - HW311 25003
- 15KV UL Type MV-105, MC-HL, CT Shielded, EPR - HW311 35003
- 15KV UL Type MV-105, MC-HL, CT Shielded, EPR - HW311 50003
Specifications:
- Impervious Continuously Welded Armor - Power Cable
- 15KV UL Type MV-105, MC-HL, CT Use, 105°C
- Shielded, EPR Insulation
- 133% Insulation Level
- Aluminum Armor
- Copper Conductors
Application:
For use in harsh environments where maximum conductor protection is required. Used for primary power and feeder circuits in a broad range of commercial and industrial power distribution systems. Approved for use in wet or dry locations at 105°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 15000 volts. UL listed, Type MC-HL per UL 2225 for use in Class I, Division I hazardous locations. UL approved for use at 105°C for continuous operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded and corrugated aluminum armor cable is recommended as an economical alternative to wire in conduit systems.
Conductors:
Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact), with a semi-conducting conductor shield.
Insulation:
Ethylene propylene rubber (EPR) per ICEA S-97-682/S-93-639 with a semi-conducting insulation shield.
Shield:
Uncoated 5 mil copper tape with a minimum 12.5% overlap per ICEA S-97-682.
Grounding Conductor:
Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1072.
Armor:
Impervious continuously welded and corrugated aluminum.
Jacket:
Red flame-retardant and sunlight-resistant PVC.
Flame Tests:
ICEA 70,000 BTU/hr and 210,000 BTU/hr flame test
Color Code:
ICEA Method 4
Additional Standards:
- UL listed, NEC Type MV-105 and Type MC, UL Standard 1072
- Single conductors are qualified per AEIC CS8
- Meets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test
- UL listed Type CWCMC to IEEE 45/IEEE 1580 (46 CFR Part 111.60-23) Marine Shipboard Cable.
Connectors:
- Explosion Proof, Class I Division 1: 424MA series - all nickel-plated aluminum
- Rain Tight: 416MC series - all nickel-plated brass
Size AWG/kcmil |
No. of Strands | Net Weight Lbs./Mft |
Catalog Number | Action |
2 | 7 | 2790 | HW311 00203 / HW31100203 |
Request A Quote |
1 | 19 | 3180 | HW311 00103 / HW31100103 |
Request A Quote |
1/0 | 19 | 3425 | HW311 10103 / HW31110103 |
Request A Quote |
2/0 | 19 | 3850 | HW311 20103 / HW31120103 |
Request A Quote |
4/0 | 19 | 4950 | HW311 40103 / HW31140103 |
Request A Quote |
250 | 19 | 5700 | HW311 25003 / HW31125003 |
Request A Quote |
350 | 37 | 7030 | HW311 35003 / HW31135003 |
Request A Quote |
500 | 37 | 8690 | HW311 50003 / HW31150003 |