Corning 12 to 72 Fiber Single and Multimode Indoor/Outdoor Oil Resistant Light Armored Cable
Select gauge from drop-down menu for prices:
- Corning 012TRV-T3B38P2P 12 Fiber 50 µm MM U-DQ(ZN)2Y4Y(SR)H 1x12 50/125 ClearCurve I/O Oil Resistant Light Armored Cable
- Corning 024TRV-T3B38P2P 24 Fiber 50 µm MM U-DQ(ZN)2Y4Y(SR)H 2x12 50/125 ClearCurve I/O Oil Resistant Light Armored Cable
- Corning 036TRV-T3B38P2P 36 Fiber 50 µm MM U-DQ(ZN)2Y4Y(SR)H 3x12 50/125 ClearCurve I/O Oil Resistant Light Armored Cable
- Corning 048TRV-T3B38P2P 48 Fiber 50 µm MM U-DQ(ZN)2Y4Y(SR)H 4x12 50/125 ClearCurve I/O Oil Resistant Light Armored Cable
- Corning 060TRV-T3B38P2P 60 Fiber 50 µm MM U-DQ(ZN)2Y4Y(SR)H 5x12 50/125 ClearCurve I/O Oil Resistant Light Armored Cable
- Corning 072TRV-T3B38P2P 72 Fiber 50 µm MM U-DQ(ZN)2Y4Y(SR)H 6x12 50/125 ClearCurve I/O Oil Resistant Light Armored Cable
- Corning 012KRV-T3B08P2P 12 Fiber U-DQ(ZN)2Y4Y(SR)H 1x12 G62.5 MMF InfiniCor I/O Oil Resistant Light Armored Cable
- Corning 024KRV-T3B08P2P 24 Fiber U-DQ(ZN)2Y4Y(SR)H 2x12 G62.5 MMF InfiniCor I/O Oil Resistant Light Armored Cable
- Corning 036KRV-T3B08P2P 36 Fiber U-DQ(ZN)2Y4Y(SR)H 3x12 G62.5 MMF InfiniCor I/O Oil Resistant Light Armored Cable
- Corning 048KRV-T3B08P2P 48 Fiber U-DQ(ZN)2Y4Y(SR)H 4x12 G62.5 MMF InfiniCor I/O Oil Resistant Light Armored Cable
- Corning 060KRV-T3B08P2P 60 Fiber U-DQ(ZN)2Y4Y(SR)H 5x12 G62.5 MMF InfiniCor I/O Oil Resistant Light Armored Cable
- Corning 072KRV-T3B08P2P 72 Fiber U-DQ(ZN)2Y4Y(SR)H 6x12 G62.5 MMF InfiniCor I/O Oil Resistant Light Armored Cable
- Corning 012ERV-T3B22P2P 12 Fiber SM U-DQ(ZN)2Y4Y(SR)H 1x12 E9/125 SMF-28e+ I/O Oil Resistant Light Armored Cable
- Corning 024ERV-T3B22P2P 24 Fiber SM U-DQ(ZN)2Y4Y(SR)H 2x12 E9/125 SMF-28e+ I/O Oil Resistant Light Armored Cable
- Corning 036ERV-T3B22P2P 36 Fiber SM U-DQ(ZN)2Y4Y(SR)H 3x12 E9/125 SMF-28e+ I/O Oil Resistant Light Armored Cable
- Corning 048ERV-T3B22P2P 48 Fiber SM U-DQ(ZN)2Y4Y(SR)H 4x12 E9/125 SMF-28e+ I/O Oil Resistant Light Armored Cable
- Corning 060ERV-T3B22P2P 60 Fiber SM U-DQ(ZN)2Y4Y(SR)H 5x12 E9/125 SMF-28e+ I/O Oil Resistant Light Armored Cable
- Corning 072ERV-T3B22P2P 72 Fiber SM U-DQ(ZN)2Y4Y(SR)H 6x12 E9/125 SMF-28e+ I/O Oil Resistant Light Armored Cable
Corning Oil Resistant light armored loose tube, triple-jacket, cables with polyamide overcoat are designed for indoor/outdoor use where resistance against hydrocarbons such as oil and gas, as well as resistance against termites is required and enables indoor/outdoor usage and installation along pipe lines.By using polyamide instead of a heavy lead sheath, these cables are easier to handle and install. Therefore, they are less hazardous for personal health and for the environment.In addition, the corrugated steel tape armoring used for light duty and heavy duty industrial direct buried applications reduces the risk of inadvertent fibre damage protecting the cables against rodents and preventing network failures. The high-density polyethylene (HDPE) inner jacket with extra aramid yarns provide extra protection and a high tensile strength and crush resistance allowing the cables to be installed where they are exposed to higher vertical forces.Corning Light Duty cable is flame-retardant and designed to resist fires up to given standards.
Features And Benefits:
• Waterblocking technology - OSP (outdoor) applications
• Corrugated steel armoring - For rodent and mechanical protection
• UV- and microbe-resistant - Can be installed in ducts or conduits or direct buried
• Dry cable core by means of water swellable elements - Allows efficient and craft-friendly cable preparation
• Fibers/buffer tubes color coded to Telcordia-Bellcore - Easy identification of the individual tubes and fibers
• SZ-stranded, loose tube design - Isolates fibers from installation and environmental rigors and facilitates mid-span access
• High-density polyethylene (HDPE) inner jacket - Increases crush and impact resistance
• Polyamide Overcoat - Additional abrasion resistance and easy installation, protection againgst hydrocarbons or termites
• Outer FR material - Enables indoor/outdoor usage and installation along pipe lines
General Specifications:
• Environment: Indoor/Outdoor
• Application: Conduits, Duct, Direct Buried
• Cable Type: Loose Tube
• Product Type: Heavy Duty Oil & Gas Cable
• Flame Rating: LSZH™/FRNC
• Fiber Category: 50 µm MM (OM2)
• Coding according to EN 60794-1-1 (DIN VDE 0888-100-1): U-DQ(ZN)2Y4Y(SR)H
Standards:
• Flame Test Method: Flame retardant according to IEC 60332-1-2 (single cable), Flame retardant to IEC 60332-3-24 (bunch of cables), Zero Halogen to IEC 60754-1, Non-corrosive according to IEC 60754-2 (FRNC) and EN 50267
• Waterblocking: IEC 60794-1-2 F5
Temperature Range:
• Installation: -40 °C to 70 °C
• Operation: -40 °C to 70 °C
• Storage: -40 °C to 85 °C
Mechanical Characteristics Cable:
• Nominal Outer Diameter: 15.7 mm
• Min. Bend Radius Installation: 314 mm
• Min. Bend Radius Operation: 235 mm
• Max. Tensile Strength for Installation: 4500 N
• Crush Resistance: 3000 N/10 cm
Chemical Characteristics
• RoHS: Free of hazardous substances according to RoHS 2011/65/EU