Belden 12 AWG CSA Control 600V TECK 90 7x20 Armored Unshielded Cable

Belden 12 AWG CSA Control 600V TECK 90 7x20 Armored Unshielded Cable

Product Details

Suitable for use in 300V, 600V or some 1000V environments, Belden offers a complete line of unarmored CSA-rated control, instrumentation and power cables.

Combined with a wide range of conductor, insulation and jacket options, Belden has the right cable solution to fit your needs.

Benefits:
• Eliminates the need for costly conduit or burial piping
• Provides superior mechanical protection for use in underground or hazardous environments
• Resists sunlight, chemicals and oil for long-life performance

Features:
• Designed specifically to meet CSA22.2 Type CIC standard
• Wide range of conductor and pair counts
• Armored options available

Ground Wire:
• Ground Wire (Y/N): Y
• Ground Wire AWG: 14
• Ground Wire Stranding: 7x22
• Conductor Material: BC - Bare Copper

Insulation:
• Material: XLP - Cross Linked Polyolefin

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 1.194
• Nom. Dia. (mm): 10.363
• Outer Jacket over Armor (y/n): Y

Outer Jacket over Armor:
• OJ Over Armor Material : PVC - Polyvinyl Chloride
• Dia. (mm): 18.517

Armor:
• Armor Type: Interlocked
• Armor Material: Aluminum
• Diameter over Armor: 0.633

Mechanical Charactertistics (Overall):
• Installation Temperature Range: -25°C To +90°C
• Wet Temperature Range: -40°C To +90°C
• Dry Temperature Range: -40°C To +90°C
• Bulk Cable Weight: 225 lbs/1000 ft.
• Max. Recommended Pulling Tension: 200 lbs.
• Min. Bend Radius/Minor Axis: 8.750 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• CSA Specification: C22.2 #131; Hazardous Location; C22.2 #0.3 Clause 4.31 Low Acid Gas
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2006
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 1.65
• Max. Operating Voltage - Non-UL: 600 V RMS
• Max. Recommended Current: 20 Amps/Conductor @ 25°C

Flame Test:
• CSA Flame Test: FT4

Plenum/Non-Plenum:
• Plenum (Y/N): No

awg # conductors overall cable-
nominal
dia. (mm)
belden cable
part
number
Action
12 2 - C5530 Request A Quote
12 3 - C5531 Request A Quote
12 4 - C5532 Request A Quote
12 5 - C5533 Request A Quote
12 6 - C5534 Request A Quote
12 7 21.844 C5535 Request A Quote
12 8 - C5536 Request A Quote
12 10 - C5538 Request A Quote
12 12 - C5540 Request A Quote
12 15 - C5543 Request A Quote
12 20 - C5548 Request A Quote
12 25 - C5553 Request A Quote
12 30 - C5558 Request A Quote

QUESTIONS & ANSWERS