Belden C5530 12 AWG 2 Conductors 600V TECK 90 Armored Unshielded Cable
Select gauge from drop-down menu for prices:
- Belden 12 AWG CSA Control 600V TECK 90 7x20 Armored Unshielded Cable
- Belden C5531 12 AWG 3 Conductors 600V TECK 90 Armored Unshielded Cable
- Belden C5532 12 AWG 4 Conductors 600V TECK 90 Armored Unshielded Cable
- Belden C5533 12 AWG 5 Conductors 600V TECK 90 Armored Unshielded Cable
- Belden C5534 12 AWG 6 Conductors 600V TECK 90 Armored Unshielded Cable
- Belden C5535 12 AWG 7 Conductors 600V TECK 90 Armored Unshielded Cable
- Belden C5536 12 AWG 8 Conductors 600V TECK 90 Armored Unshielded Cable
- Belden C5538 12 AWG 10 Conductors 600V TECK 90 Armored Unshielded Cable
- Belden C5540 12 AWG 12 Conductors 600V TECK 90 Armored Unshielded Cable
- Belden C5543 12 AWG 15 Conductors 600V TECK 90 Armored Unshielded Cable
- Belden C5548 12 AWG 20 Conductors 600V TECK 90 Armored Unshielded Cable
- Belden C5553 12 AWG 25 Conductors 600V TECK 90 Armored Unshielded Cable
- Belden C5558 12 AWG 30 Conductors 600V TECK 90 Armored Unshielded Cable
Description:
• 12 AWG stranded (7x20) bare copper conductors, 14 AWG bare copper ground wire, aluminum interlocked armor, .030” (.76mm) XLPE insulation, PVC inner jacket, PVC outer jacket.
Ground Wire:
• Ground Wire (Y/N): Y
• Ground Wire AWG: 14
• Ground Wire Stranding: 7x22
• Conductor Material: BC - Bare Copper
Insulation:
• Material: XLP - Cross Linked Polyolefin
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 1.194
• Nom. Dia. (mm): 10.363
• Outer Jacket over Armor (y/n): Y
Outer Jacket over Armor:
• OJ Over Armor Material : PVC - Polyvinyl Chloride
• Dia. (mm): 18.517
Armor:
• Armor Type: Interlocked
• Armor Material: Aluminum
• Diameter over Armor: 0.633
Mechanical Charactertistics (Overall):
• Installation Temperature Range: -25°C To +90°C
• Wet Temperature Range: -40°C To +90°C
• Dry Temperature Range: -40°C To +90°C
• Bulk Cable Weight: 225 lbs/1000 ft.
• Max. Recommended Pulling Tension: 200 lbs.
• Min. Bend Radius/Minor Axis: 8.750 in.
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• CSA Specification: C22.2 #131; Hazardous Location; C22.2 #0.3 Clause 4.31 Low Acid Gas
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2006
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Electrical Characteristics (Overall):
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 1.65
• Max. Operating Voltage - Non-UL: 600 V RMS
• Max. Recommended Current: 20 Amps/Conductor @ 25°C
Flame Test:
• CSA Flame Test: FT4
Plenum/Non-Plenum:
• Plenum (Y/N): No
technical specification: | |
awg | 12 |
# conductors | 2 |
stranding | 7x20 |
no. of conductors | 2 |
conductor material | bare copper |
outer shield - material | unshielded |
overall cable- nominal dia. (mm) | - |
belden cable part number | C5530 |