Belden 8110 Cable 24 AWG 10 Pairs Overall Foil/Braid Shield Low Cap. Computer Cables for EIA RS-232/422 Applications TC Stranded 7x32 Cable

Belden 8110 Cable 24 AWG 10 Pairs Overall Foil/Braid Shield Low Cap. Computer Cables for EIA RS-232/422 Applications TC Stranded 7x32 Cable

Select gauge from drop-down menu for prices:

Belden 8110 Cable 24 AWG 10 Pairs Overall Foil/Braid Shield Low Cap. Computer Cables for EIA RS-232/422 Applications TC Stranded 7x32 Cable

Precio habitual $16.50 $12.62 Oferta /per Foot

Belden 8110 Cable 24 AWG 10 Pairs Overall Foil/Braid Shield Low Cap. Computer Cables for EIA RS-232/422 Applications TC Stranded 7x32 Cable

Description:
• 24 AWG stranded (7x32) TC conductors, Datalene® insulation, twisted pairs, overall Beldfoil® (100% coverage) + TC braid shield (65% coverage), 24 AWG stranded TC drain wire, PVC jacket.

Insulation:
• Trade Name: Datalene®
• Material: FPE - Foam Polyethylene
• Wall Thickness (mm): 0.3302

Outer Shield Drain Wire AWG:
• AWG: 24
• Stranding: 7x32
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.889

Mechanical Charactertistics (Overall):
• Operating Temperature Range: -30°C To +80°C
• UL Temperature Rating: 80°C (UL AWM Style 2919)
• Bulk Cable Weight: 82 lbs/1000 ft.
• Max. Recommended Pulling Tension: 115.500 lbs.
• Min. Bend Radius/Minor Axis: 4.500 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CM
• CEC/C(UL) Specification: CM
• AWM Specification: UL Style 2919 (30 V 80°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 100
• Nom. Capacitance Conductor to Conductor (pF/ft): 12.5
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/ft): 22
• Nominal Velocity of Propagation (VP %): 78
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 24
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 2.4
• Max. Operating Voltage - UL: 30 V RMS (UL AWM Style 2919)
• Max. Operating Voltage - UL: 300 V RMS (CM)
• Max. Recommended Current: 1.1 Amps/Conductor @ 25°C

Flame Test:
• UL Flame Test: UL1685 UL Loading

Plenum/Non-Plenum:
• Plenum (Y/N): No

technical specification:
awg 24
# pairs 10
stranding 7x32
no. of conductors 20
conductor material tinned copper
outer shield - type tape
outer shield - material aluminum foil-polyester tape w/shorting fold
overall cable- nominal dia. (mm) 10.846
belden cable part number 8110