Belden 1032A 18 AWG 1 Pair 300V PLTC Multi Conductor Cable
Select gauge from drop-down menu for prices:
- Belden 18 AWG Pairs 300V PLTC Overall Beldfoil Shield Orange Communication Cable
- Belden 3025A 18 AWG 2 Pairs 300V PLTC Multi Conductor Cable
- Belden 1529A 18 AWG 3 Pairs 300V PLTC Multi Conductor Cable
- Belden 1466A 18 AWG 4 Pairs 300V PLTC Multi Conductor Cable
- Belden 1467A 18 AWG 8 Pairs 300V PLTC Multi Conductor Cable
- Belden 1468A 18 AWG 12 Pairs 300V PLTC Multi Conductor Cable
- Belden 3034A 18 AWG 16 Pairs 300V PLTC Multi Conductor Cable
- Belden 1471A 18 AWG 24 Pairs 300V PLTC Multi Conductor Cable
- Belden 1472A 18 AWG 36 Pairs 300V PLTC Multi Conductor Cable
- Belden 3041A 18 AWG 50 Pairs 300V PLTC Multi Conductor Cable
Product Details
Description:
• 18 AWG pairs stranded (7x26) bare copper conductors, twisted pairs, PVC insulation, overall Beldfoil® shield (100% coverage), PVC jacket.
Insulation:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness (mm): 0.406
Outer Shield Drian Wire AWG:
• AWG: 20
• Stranding: 7x28
• Material: TC - Tinned Copper
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.9398
• Outer Jacket Ripcord: Yes
Mechanical Charactertistics (Overall):
• Operating Temperature Range: -30°C To +105°C
• Bulk Cable Weight: 48.367 Kg/Km
• Max. Recommended Pulling Tension: 115.653 N
• Min. Bend Radius/Minor Axis: 24.130 mm
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMG, ITC-ER, PLTC-ER
• CEC/C(UL) Specification: CMG
• AWM Specification: UL Style 2464 (300 V 80°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Electrical Characteristics (Overall):
• Nom. Inductance (?H/m): 0.62339
• Nom. Capacitance Conductor to Conductor (pF/m): 167.331
• Nom. Capacitance Cond. to Other Conductor and Shield (pF/m): 311.695
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 19.2267
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/km): 16.6347
• Max. Operating Voltage - UL: 300 V RMS (PLTC, CMG)
• Max. Operating Voltage - UL: 150 V RMS (ITC)
• Max. Recommended Current: 8 Amps/Conductor @ 25°C
Flame Test:
• UL Flame Test: UL1685 UL Loading
• CSA Flame Test: FT4
• IEEE Flame Test: 1202
Suitability:
• Suitability - Burial: No
• Sunlight Resistance: Yes
Plenum/Non-Plenum:
• Plenum (Y/N): No
technical specification: | |
awg | 18 |
# pairs | 1 |
stranding | 7x26 |
no. of conductors | 2 |
conductor material | bare copper |
outer shield - type | tape |
outer shield - material | aluminum foil-polyester tape |
overall cable- nominal dia. (mm) | 6.020 |
belden cable part number | 1032A |