Belden 6341PC Cable 18 AWG 2 Pairs Security Pro and Intercom Audio Plenum CMP Stranded BC Flamarrest Jacket Cable

Belden 6341PC Cable 18 AWG 2 Pairs Security Pro and Intercom Audio Plenum CMP Stranded BC Flamarrest Jacket Cable

Select gauge from drop-down menu for prices:

Belden 6341PC Cable 18 AWG 2 Pairs Security Pro and Intercom Audio Plenum CMP Stranded BC Flamarrest Jacket Cable

Regular price $1.90 $1.46 Sale /per Foot

Belden 6341PC Cable 18 AWG 2 Pairs Security Pro and Intercom Audio Plenum CMP Stranded BC Flamarrest Jacket Cable

Description:
• Security, Pro Audio & Intercom Cable, Plenum-CMP, 2-18 AWG stranded bare copper pairs with FEP insulation, Individually Beldfoil® shielded and Flamarrest® jacket

Insulation:
• Material: LS PVC - Low Smoke Polyvinyl Chloride
• Wall Thickness (mm): 0.254

Inner Shield:
• Type: Tape
• Material: Aluminum Foil-Polyester Tape

Inner Shield Drain Wire AWG:
• AWG: 24
• Stranding: 7
• Material: TC - Tinned Copper

Outer Jacket:
• Trade Name: Flamarrest®
• Material: LS PVC - Low Smoke Polyvinyl Chloride
• Nom. Wall Thickness (mm): 4.191
• Outer Jacket Ripcord: Yes

Pair Lay Length and Direction:
• Lay Length (mm): 47.625

Mechanical Charactertistics (Overall):
• UL Tempeature Rating: 75°C
• Bulk Cable Weight: 43.300 lbs/1000 ft.
• Max. Recommended Pulling Tension: 117.600 lbs.
• Min. Bend Radius/Minor Axis: 2.750 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMP
• CEC/C(UL) Specification: CMP
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Inductance (μH/ft): 0.16
• Nom. Capacitance Conductor to Conductor (pF/ft): 44
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/ft): 79.2
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 6.500
• Nominal Inner Shield DC Resistance @ 20°C (Ohm/1000 ft): 14.400
• Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 14.400 Ohm/1000 ft
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 4 Amps/Conductor @ 25°C

Flame Test:
• UL Flame Test: NFPA 262
• C(UL) Flame Test: FT6

Plenum/Non-Plenum:
• Plenum (Y/N): Yes

technical specification:
awg 18
# conductors -
stranding 7
no. of conductors 4
conductor material bare copper
dia. (mm) -
outer shield - type -
outer shield - material unshielded
overall cable- nominal dia, (mm.) 7.137
belden cable part number 6341PC