Belden 6548PA Cable 22 AWG 12 Pairs Security Pro and Intercom Audio Plenum CMP Stranded BC PVDF Jacket Cable

Belden 6548PA Cable 22 AWG 12 Pairs Security Pro and Intercom Audio Plenum CMP Stranded BC PVDF Jacket Cable

Select gauge from drop-down menu for prices:

Belden 6548PA Cable 22 AWG 12 Pairs Security Pro and Intercom Audio Plenum CMP Stranded BC PVDF Jacket Cable
Belden 6548PA Cable 22 AWG 12 Pairs Security Pro and Intercom Audio Plenum CMP Stranded BC PVDF Jacket Cable

Description:
• Security, Pro Audio & Intercom Cable, Plenum-CMP, 12-22 AWG stranded bare copper pairs with FEP insulation, Individually Beldfoil® shielded and PVDF jacket with ripcord

Insulation:
• Trade Name: Teflon®
• Material: FEP - Fluorinated Ethylene Propylene
• Wall Thickness (mm): 0.254
• Dia. (mm): 1.2446

Inner Shield:
• AWG: 24
• Material: TC - Tinned Copper

Inner Shield Drain Wire AWG:
• AWG: 24
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVDF - Fluorocopolymer
• Nom. Wall Thickness (mm): 0.4318
• Outer Jacket Ripcord: Yes

Pair Lay Length and Direction):
• Lay Length (mm): 34.925
• Twist (twist/ft): 6.900

Mechanical Charactertistics (Overall):
• Operating Temperature Range: -20°C To +150°C
• UL Tempeature Rating: 75°C
• Bulk Cable Weight: 172.631 Kg/Km
• Max. Recommended Pulling Tension: 971.487 N
• Min. Bend Radius/Minor Axis: 101.600 mm

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMP
• NEC Articles: 800
• CEC/C(UL) Specification: CMP
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 50
• Nom. Inductance (μH/ft): 0.18
• Nom. Capacitance Conductor to Conductor (pF/ft): 27.5
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/ft): 49.5
• Nominal Velocity of Propagation (VP %): 69
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 16.4
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 15.3
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 1.5 Amps/Conductor @ 25°C

Flame Test:
• UL Flame Test: NFPA 262
• C(UL) Flame Test: FT6

Plenum/Non-Plenum:
• Plenum (Y/N): Yes

technical specification:
awg 22
# conductors -
stranding 7x30
no. of conductors 24
conductor material bare copper
dia. (mm) 0.7366
outer shield - type -
outer shield - material unshielded
overall cable- nominal dia, (mm.) 10.363
belden cable part number 6548PA