General Cable Armored Instrumentation XLPE 16 Gauge 12 Pairs Individual and Overall Shield UL Type ITC-HL PLTC 300V Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
Select gauge from drop-down menu for prices:
- General Cable Armored Instrumentation XLPE Pairs Triads Individual and Overall Shield UL Type ITC-HL PLTC 300V Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation XLPE 16 Gauge 1 Pairs Individual and Overall Shield UL Type ITC-HL PLTC 300V Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation XLPE 16 Gauge 16 Pairs Individual and Overall Shield UL Type ITC-HL PLTC 300V Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation XLPE 16 Gauge 2 Pairs Individual and Overall Shield UL Type ITC-HL PLTC 300V Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation XLPE 16 Gauge 24 Pairs Individual and Overall Shield UL Type ITC-HL PLTC 300V Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation XLPE 16 Gauge 36 Pairs Individual and Overall Shield UL Type ITC-HL PLTC 300V Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation XLPE 16 Gauge 4 Pairs Individual and Overall Shield UL Type ITC-HL PLTC 300V Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation XLPE 16 Gauge 50 Pairs Individual and Overall Shield UL Type ITC-HL PLTC 300V Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation XLPE 16 Gauge 8 Pairs Individual and Overall Shield UL Type ITC-HL PLTC 300V Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation XLPE 16 Gauge 1 Triads Individual and Overall Shield UL Type ITC-HL PLTC 300V Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation XLPE 16 Gauge 2 Triads Individual and Overall Shield UL Type ITC-HL PLTC 300V Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation XLPE 16 Gauge 4 Triads Individual and Overall Shield UL Type ITC-HL PLTC 300V Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation XLPE 16 Gauge 8 Triads Individual and Overall Shield UL Type ITC-HL PLTC 300V Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation XLPE 16 Gauge 12 Triads Individual and Overall Shield UL Type ITC-HL PLTC 300V Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation XLPE 16 Gauge 16 Triads Individual and Overall Shield UL Type ITC-HL PLTC 300V Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation XLPE 16 Gauge 24 Triads Individual and Overall Shield UL Type ITC-HL PLTC 300V Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation XLPE 16 Gauge 36 Triads Individual and Overall Shield UL Type ITC-HL PLTC 300V Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation XLPE 16 Gauge 50 Triads Individual and Overall Shield UL Type ITC-HL PLTC 300V Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
Conductor:
• Bare annealed copper per ASTM B3
• Class B stranding per ASTM B8
Insulation:
• Cross-Linked Polyethylene (XLPE), rated 90°C per UL Standards 13 and 2250
• Color-coded per ICEA Method 1: pairs – black and white; triads – black, white and red. Each conductor in each pair or triad is printed alphanumerically for easy identification
Shielded Pairs/Triads:
• Isolated and individually twisted pairs or triads with a Flexfoil® aluminum/ polyester tape shield providing 100% coverage
• Stranded tinned copper drain wire, two sizes smaller than insulated conductors
Cable Assembly:
• Individually shielded pairs or triads and communication wire are cabled together with a left-hand lay
• Communication wire: 20 AWG solid bare copper, Cross-Linked Polyethylene (XLPE), rated 90°C, orange
Overall Shield:
• Flexfoil® aluminum/polyester tape shield providing 100% coverage
• Stranded tinned copper drain wire, same size as insulated conductors
Inner Jacket:
• Flame-retardant Polyvinyl Chloride (PVC) per UL Standards 13 and 2250, black
• Low temperature performance meets ASTM D746 brittleness temperature at or below -40°C
• Nylon rip cord to facilitate jacket removal
CCW Armor:
• Impervious, continuously welded and corrugated aluminum alloy sheath per UL 1569
• CCW armor conductivity meets the grounding requirements of NEC Article 250
Overall Jacket:
• Flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC) per UL Standards 13 and 2250, black
• Low temperature performance meets ASTM D746 brittleness temperature at or below -40°C
Applications:
• CCW armored Instrumentation cables with individually shielded pairs or triads and an overall shield provide superior protection and reliability against physical damage for use in instrumentation and process control applications requiring ITC-HL or PLTC wiring methods where shielding against both external EMI and EMI between groups is required
• For use as Power Limited Tray Cable on circuits rated 150 V or less and 5 amps or less in Class 2 or Class 3 circuits in accordance with NEC Article 725
• For use as Instrumentation Tray Cable on circuits rated 150 V or less and 5 amps or less in accordance with NEC Article 727
• Recognized for use in Class I and III, Divisions 1 and 2; Class II, Division 2; or Class I, Zones 1 and 2 hazardous locations per NEC Articles 501, 502, 503 and 505
• Installed indoors or outdoors, in wet or dry locations, in a raceway, as aerial cable on a messenger, in cable trays, or for direct burial
• Recognized for use on fixed or floating offshore petroleum facilities as recommended by the American Petroleum Institute
Features:
• CCW armor provides superior mechanical protection and an impervious barrier to moisture, gas and liquids
• CCW armor provides EMI shielding performance
• Meets cold impact at -40°C
Specifications:
Design Adherence:
• UL 13 Power-Limited Circuit Cables
• UL 2250 Instrumentation Tray Cable
• UL 1569 Metal Clad Cables
• UL 1309/CSA C22.2 No. 245 Marine Shipboard Cable
Flame Tests:
• ICEA T-29-520 (210,000 BTU/hr)
• IEEE 383 (70,000 BTU/hr)
• CSA FT4
• IEEE 1202 (70,000 BTU/hr)
• UL 1581 (70,000 BTU/hr)
• IEC 60332-3 Cat. A
Compliances:
• UL Type PLTC, SUN RES, DIR BUR, -40°C, UL File # E36118
• UL Type ITC-HL, UL File # E177408
• UL Listed Marine Shipboard, UL File # E85994
• American Bureau of Shipping (ABS) Listed for CWCMC
• RoHS Compliant
technical specification: | |
cond. size (awg)
|
16 |
no. of pairs | 12 |
insulation thickness (mils) | 30 |
insulation thickness (mm) | 0.76 |
communication wiresizeawg | 20 |
communication wireins. thickness(mils) | 15 |
communication wireins. thickness(mm) | 0.38 |
inner jacket thickness (mils) | 109 |
inner jacket thickness (mm) | 2.77 |
nominal core o.d. (inches) | 1.17 |
nominal core o.d. (mm)
|
29.7 |
nominal armor o.d. (inches) | 1.52 |
nominal armor o.d.(mm) | 38.6 |
jacket thickness (mils) | 60 |
jacket thickness (mm) | 1.52 |
nominal overall o.d. (inches) | 1.65 |
nominal overall o.d. (mm) | 41.9 |
crosssectional area¹sq. in. | 2.17 |
approximate net weight (lbs/1000 ft)
|
1,075 |
approximate net weight (kg/1000 m) | 1,600 |
catalog number | 9150.16121201 |