Belden 82505 Cable 24 AWG 5 Pairs Overall Beldfoil Shield Plenum Rated Computer Cables for EIA RS-232 Application Multi Conductor Cable

Belden 82505 Cable 24 AWG 5 Pairs Overall Beldfoil Shield Plenum Rated Computer Cables for EIA RS-232 Application Multi Conductor Cable

Select gauge from drop-down menu for prices:

Belden 82505 Cable 24 AWG 5 Pairs Overall Beldfoil Shield Plenum Rated Computer Cables for EIA RS-232 Application Multi Conductor Cable

Precio habitual $11.03 $7.75 Oferta /per Foot

Belden 82505 Cable 24 AWG 5 Pairs Overall Beldfoil Shield Plenum Rated Computer Cables for EIA RS-232 Application Multi Conductor Cable

Description:
• 24 AWG stranded (7x32) TC conductors, plenum, FEP insulation, twisted pair, overall Beldfoil shield (100% coverage), 24 AWG stranded TC drain wire, Flamarrest® jacket.

Insulation:
• Material: FEP - Fluorinated Ethylene Propylene
• Wall Thickness (mm): 0.1524

Outer Shield Drain Wire AWG:
• AWG: 24
• Stranding: 7x32
• Material: TC - Tinned Copper

Outer Jacket:
• Trade Name: Flamarrest®
• Material: LS PVC - Low Smoke Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.381

Mechanical Charactertistics (Overall):
• Operating Temperature Range: 0°C To +75°C
• Bulk Cable Weight: 41.670 Kg/Km
• Max. Recommended Pulling Tension: 271.340 N
• Min. Bend Radius/Minor Axis: 50.800 mm

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMP
• CEC/C(UL) Specification: CMP
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Inductance (μH/m): 0.55777
• Nom. Capacitance Conductor to Conductor (pF/m): 82.025
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/m): 147.645
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 79.0721
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/km): 49.215
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 1.5 Amps/Conductor @ 25°C

Flame Test:
• UL Flame Test: NFPA 262
• CSA Flame Test: FT6

Plenum/Non-Plenum:
• Plenum (Y/N): Yes

technical specification:
awg 24
# pairs 5
stranding 7x32
no. of conductors 10
conductor material tinned copper
outer shield - type tape
outer shield - material aluminum foil-polyester tape
overall cable- nominal dia. (mm) 4.978
belden cable part number 82505

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question