Helukabel 2/0 AWG 3 Cores TOPFLEX-EMV-UV-3 PLUS 2YSLCYK-J UL/CSA Motor Supply Cable 1000 V Double Screened Meter Marking Cable 22225
Select gauge from drop-down menu for prices:
- Helukabel Topflex-EMV-UV-3 PLUS 2YSLCYK-J UL/CSA Motor Supply Cable 1000 V Double Screened Meter Marking Cable
- Helukabel 16 AWG 3 Cores TOPFLEX-EMV-UV-3 PLUS 2YSLCYK-J UL/CSA Motor Supply Cable 1000 V Double Screened Meter Marking Cable 22193
- Helukabel 14 AWG 3 Cores TOPFLEX-EMV-UV-3 PLUS 2YSLCYK-J UL/CSA Motor Supply Cable 1000 V Double Screened Meter Marking Cable 22194
- Helukabel 12 AWG 3 Cores TOPFLEX-EMV-UV-3 PLUS 2YSLCYK-J UL/CSA Motor Supply Cable 1000 V Double Screened Meter Marking Cable 22195
- Helukabel 10 AWG 3 Cores TOPFLEX-EMV-UV-3 PLUS 2YSLCYK-J UL/CSA Motor Supply Cable 1000 V Double Screened Meter Marking Cable 22196
- Helukabel 8 AWG 3 Cores TOPFLEX-EMV-UV-3 PLUS 2YSLCYK-J UL/CSA Motor Supply Cable 1000 V Double Screened Meter Marking Cable 22197
- Helukabel 6 AWG 3 Cores TOPFLEX-EMV-UV-3 PLUS 2YSLCYK-J UL/CSA Motor Supply Cable 1000 V Double Screened Meter Marking Cable 22198
- Helukabel 4 AWG 3 Cores TOPFLEX-EMV-UV-3 PLUS 2YSLCYK-J UL/CSA Motor Supply Cable 1000 V Double Screened Meter Marking Cable 22199
- Helukabel 2 AWG 3 Cores TOPFLEX-EMV-UV-3 PLUS 2YSLCYK-J UL/CSA Motor Supply Cable 1000 V Double Screened Meter Marking Cable 22223
- Helukabel 1 AWG 3 Cores TOPFLEX-EMV-UV-3 PLUS 2YSLCYK-J UL/CSA Motor Supply Cable 1000 V Double Screened Meter Marking Cable 22224
- Helukabel 3/0 AWG 3 Cores TOPFLEX-EMV-UV-3 PLUS 2YSLCYK-J UL/CSA Motor Supply Cable 1000 V Double Screened Meter Marking Cable 22226
- Helukabel 4/0 AWG 3 Cores TOPFLEX-EMV-UV-3 PLUS 2YSLCYK-J UL/CSA Motor Supply Cable 1000 V Double Screened Meter Marking Cable 22227
- Helukabel 300 MCM 3 Cores TOPFLEX-EMV-UV-3 PLUS 2YSLCYK-J UL/CSA Motor Supply Cable 1000 V Double Screened Meter Marking Cable 22228
- Helukabel 350 MCM 3 Cores TOPFLEX-EMV-UV-3 PLUS 2YSLCYK-J UL/CSA Motor Supply Cable 1000 V Double Screened Meter Marking Cable 22229
- Helukabel 500 MCM 3 Cores TOPFLEX-EMV-UV-3 PLUS 2YSLCYK-J UL/CSA Motor Supply Cable 1000 V Double Screened Meter Marking Cable 22230
Technical data:
• Special motor power supply cable for frequency converters to Style 2570
Temperature range
• flexing -5°C bis +80°C
• fixed installation -40°C bis +80°C
Nominal voltage
• UL 1000 V
Test voltage
• 4000 V
Insulation resistance
• min. 200 MOhm x km
Coupling resistance
• acc. to different cross-section max. 250 Ohm/km
Minimum bending radius
• fixed installation for outer Ø:
up to 12 mm: 5x cable Ø
> 12-20 mm: 7,5x cable Ø
> 20 mm: 10x cable Ø
• free-movement for outer Ø:
up to 12 mm: 10x cable Ø
> 12-20 mm: 15x cable Ø
> 20 mm: 20x cable Ø
Radiation resistance
• up to 80x106 cJ/kg (up to 80 Mrad)
Cable structure:
• Bare copper, fine wire conductor to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5
• Core insulation of polyethylene (PE)
• Core identification BK, BN, GY
• GN-YE conductor (divided into 3)
• Cores stranded in concentric layers
• 3+3 core design
1. Screen with special aluminium film
2. Tinned copper braided screen, approx. 85% coverage
• Outer sheath of special PVC
• Sheath colour black (RAL 9005)
• with meter marking
Properties:
• Low mutual capacitance
• Meets EMC requirements acc. to EN 55011 and DIN VDE 0875 part 11
• Low coupling resistance for high electromagnetic compatibility
• Due to the optimal screening an interference-free operation of frequency converters is obtained
• The 3 Plus-construction of motor power supply cables features a symmetrical 3-core design, improved in terms of EMC characteristics comparing favorably with a 4-core version. The protective conductor PE, divided into 3 is uniformly stranded in the interstices. This enables an extremely concentric structure
• The minimum cross-section of 0,752 meets the requirements of DIN EN 60204 part 1
• uv-resistant
• Outdoor application
• This screened motor supply cable with low mutual capacitance of the single cores because of the special PE core insulation and low screen capacitance enable a low-loss transmission of the power compared to PVC-sheathed connecting cables
• The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers
Tests:
• PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)
Note:
• **) The current carrying capacity for permanent operation at ambient temperature of 30°C. For deviating ambient temperatures the conversion factors should be used and for further see the indication in DIN VDE 0298 part 4.
• AWG sizes are approximate equivalent values. The actual cross-section is in mm².
Application:
It is used as a connection and connecting cable under average mechanical stress for fixed installation and sometimes for free movement in dry, moist and wet rooms and outside. It is used in the automotive industry, food processing industry, transfer streets, packaging industry, machine tools, handling equipment, in the industry it is used for pumps, fans, transport belts and in air condition systems, etc. Used in explosion proof areas.
EMC = Electromagnetic compatibility
The screen must be connected at both end
technical specification: | |
awg-no. | 2/0 |
no.cores x cross-sec. mm² | 3 x 70 + 3 G 10,0 |
outer ø app. mm | 38,1 |
coupling resistance at 1 mhz ohm/km | 2 |
coupling resistance at 30 mhz ohm/km | 45 |
power ratings**) with 3 loaded cores in amperes | 207 |
cop. weight kg/km | 2871,0 |
weight app. kg/km | 3056,0 |
helukabel part number | 22225 |