Belden 22 AWG Category 5e DataTuff 5 Million Flex Quad Cable Multi-Conductor Shielded Stranded Tinned Copper TPE Cable 7962A
Select gauge from drop-down menu for prices:
22 AWG Symmetric quad stranded tinned copper conductors, polyolefin insulation, FRPE bedding, industrial grade sunlight- and oil-resistant TPE jacket, rip cord. Sequential marking at two foot intervals. PROFINET Type C trailing cable for continuous flex applications
Applications: Industrial Ethernet Cable, Harsh Environments, Category 5e, ProfiNet, 100BaseTX, CMX - Outdoor, PLTC Listed, Approved for Cable Tray Use in Class 1, Division 2, Hazardous Areas and Non-hazardous Areas, Cable Trays, Raceways, Conduit and Supported by Messenger Wires, Approved for Outdoor Usage
Mechanical Characteristics (Overall):
• Storage Temperature Range: -40°C To +80°C
• Installation Temperature Range: -20°C To +60°C
• Operating Temperature Range: -40°C To +80°C
• Bulk Cable Weight: 46 lbs/1000 ft.
• Max. Recommended Pulling Tension: 55 lbs.
• Min. Bend Radius/Minor Axis: 2.560 in.
Electrical Characteristics (Overall):
• Nom. Capacitance Conductor to Shield (pF/ft): 15
• Maximum Capacitance Unbalance (pF/100 m): 66
• Nominal Velocity of Propagation (VP (%)): 70
• Maximum Delay (ns/100 m): 552.000
• Maximum Conductor DC Resistance @ 20°C (Ohm/100 m): 5.700
• Max. Operating Voltage - UL: 300 V RMS
• Maximum DCR Unbalanced @ 20°C (%): 3
Applicable Standards & Environmental Programs:
• NEC/(UL) Specification: CM, CMX-Outdoor, ITC, PLTC
• CEC/C(UL) Specification: CM
• AWM Specification: UL Style 20626 (600V 80°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire & Cable): Yes
• MII Order #39 (China RoHS): Yes
• Telecommunications Standards: Category 5e - TIA 568.C.2
• Other Specification: Oil Res I, Oil Res 60811-2-1, Weldspatter Resistant
Flame Test:
• UL Flame Test: UL1666 Vertical Tray
• C(UL) Flame Test: FT1
Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes
• Sunlight Resistance: Yes
• Oil Resistance: Yes
Plenum/Non-Plenum:
• Plenum (Y/N): No
technical specifications: | |
awg | 22 |
conductors | 4 |
stranding | 19 x 34 |
conductor material | Tinned Copper |
conductor dia. | 0.028 |
insulation material | polyolefin |
insulation dia. (in.) | 0.064 |
inner jacket material | frpe |
nom. dia. (in.) | 0.167 |
overall nominal diameter (in.) | 0.276 |
belden part number | 7962A |