Belden 3119A Cable 24 AWG And 18 AWG 3 Pairs Interbus-S Polyurethane Jacket Cable

Belden 3119A Cable 24 AWG And 18 AWG 3 Pairs Interbus-S Polyurethane Jacket Cable

Select gauge from drop-down menu for prices:

Belden 3119A Cable 24 AWG And 18 AWG 3 Pairs Interbus-S Polyurethane Jacket Cable

Product Details

Description:
• 18 and 24 AWG stranded tinned copper conductors, PVC insulation (power), PE insulation (data), overall Beldfoil® shield (100% coverage) plus a tinned copper braid (90% coverage), polyurethane jacket

Insulation:
• Material: PE - Polyethylene (24 AWG) And PVC - Polyvinyl Chloride (18 AWG)

Outer Shield Drain Wire AWG:
• AWG: 24
• Stranding: 7x32
• Conductor Material: TC - Tinned Copper
• Diameter: 0.024

Outer Jacket:
• Material: PUR - Polyurethane

Mechnical Characteristics (Overall):
• Operating Temperature Range: -40°C To +80°C
• UL Temperature Rating: 80°C (UL AWM Style 20233)
• Bulk Cable Weight: 62 lbs/1000 ft.
• Max. Recommended Pulling Tension: 100 lbs.
• Min. Bend Radius/Minor Axis: 3 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards & Environmental Programs:
• AWM Specification: UL Style 20233 (300 V 80°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 10/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire & Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 100
• Nom. Capacitance Conductor Shield (pF/ft): 15.4
• Nominal Velocity of Propagation VP (%): 66 (24 AWG)
• Nominal Delay (ns/ft): 1.6
• Nom. Conductor DCR @ 20°C (Ohm/1000 ft): 23.4 (24 AWG) and 6.6 (18 AWG)
• Nom. Outer Shield DCR @ 20°C (Ohm/1000 ft): 2.7
• Max.Operating - UL: 300 V RMS (UL AWM Style 20233)
• Max. Recommended Current: 2.1 (24 AWG) and 4.8 (18 AWG)

Suitability:
• Sunlight Resistance: High

Plenum/Non-Plenum:
• Plenum (Y/N): No

Benefits:
• Easy installation and start up
• Increased space savings
• High efficiency

Features:
• Automatic configuration capability
• Protocol chips in fieldbus technology
• Low protocol overhead

technical specification:
awg 24 and 18
# pair 3
stranding 7x32 and 7x26
no. of conductors 9
conductor material tinned copper
dia. (in.) 0.024 and 0.060
outer shield - type tape and braid
outer shield - material aluminum foil-polyester tape and tinned copper
overall cable - nominal dia. (in.) 0.024
belden cable part number 3119A