Belden 7201A Cable 24 AWG 2 Pairs RS-485 Flex Data 300V Multi Conductor Stranded 41x40 BC Oil-Resistant PVC Jacket Cable
Belden 7201A Cable 24 AWG 2 Pairs RS-485 Flex Data 300V Multi Conductor Stranded 41x40 BC Oil-Resistant PVC Jacket Cable
SKU: SKU:
- Belden 7201A Cable 24 AWG 2 Pairs RS-485 Flex Data 300V Multi Conductor Stranded 41x40 BC Oil-Resistant PVC Jacket Cable
- Belden 7201A Cable 24 AWG 2 Pairs RS-485 Flex Data 300V Multi Conductor Stranded 41x40 BC Oil-Resistant PVC Jacket Cable
Shipping Available
No se pudo cargar la disponibilidad de retiro
Description:
• 24 AWG stranded (41x40) bare copper conductors, twisted pairs, foam polyethylene insulation with skin, overall Beldfoil® (100% coverage), tinned copper braid shield (85% coverage), oil-resistant PVC jacket.
Insulation:
• Material: FPE - Foam Polyethylene
• Material: PE - Polyethylene
• Resistance: 6.1 Megohms/1000 ft. minimum
Outer Shield Drain Wire AWG:
• AWG: 24
• Stranding: 41x40
• Material: TC - Tinned Copper
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
Usage (Overall):
Applications:
• Flex Data, RS232, RS485
Mechanical Characteristics (Overall):
• Operating Temperature Range: -20°C To +60°C
• UL Temperature Rating: 60°C
• Bulk Cable Weight: 43.500 lbs/1000 ft.
• Max. Recommended Pulling Tension: 68 lbs.
• Min. Bend Radius/Minor Axis: 3.200 in.
• Min. Bend Radius (Continuous Flexing): 4.500 in.
• Flex Cycle Rating: 1 Million
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CM
• CEC/C(UL) Specification: CM
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 10/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: RS Type: 232/485
Electrical Characteristics (Overall):
• Nom. Capacitance Conductor to Conductor (pF/ft): 15
• Nominal Velocity of Propagation: VP (%): 72
• Max. Operating Voltage - UL: 300 V RMS
• Differential Impedance @ 1 MHz: 120 +/-15
Flame Test:
• UL Flame Test: UL1685 UL Loading
Suitability:
• Oil Resistance: Yes
Plenum/Non-Plenum:
• Plenum(Y/N): No
technical specification: | |
awg | 24 |
# pairs | 2 |
stranding | 41x40 |
no. of conductors | 4 |
conductor material | bare copper |
diameter (in.) | - |
outer shield - type | tape |
outer shield - material | aluminum foil-polyester tape |
overall cable - nominal diameter (in.) | 0.322 |
belden cable part number | 7201A |