Eutex Cable 1 Core 120 Nominal Area UX P15 0.6/1KV RX Earthing and Bonding Wire Cable Designation Flame Retardant
Select gauge from drop-down menu for prices:
Eutex Cable 1 Core 120 Nominal Area UX P15 0.6/1KV RX Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable Earthing and Bonding Wire Cable Designation UX P15 0.6/1KVUX, FX-UX, RX Flame Retardant
- Eutex Cable 1 Core 1.0 Nominal Area UX P15 0.6/1KV UX(Class2 Conductor) Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 1.5 Nominal Area UX P15 0.6/1KV UX(Class2 Conductor) Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 2.5 Nominal Area UX P15 0.6/1KV UX(Class2 Conductor) Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 4 Nominal Area UX P15 0.6/1KV UX(Class2 Conductor) Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 6 Nominal Area UX P15 0.6/1KV UX(Class2 Conductor) Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 10 Nominal Area UX P15 0.6/1KV UX(Class2 Conductor) Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 16 Nominal Area UX P15 0.6/1KV UX(Class2 Conductor) Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 25 Nominal Area UX P15 0.6/1KV UX(Class2 Conductor) Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 35 Nominal Area UX P15 0.6/1KV UX(Class2 Conductor) Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 50 Nominal Area UX P15 0.6/1KV UX(Class2 Conductor) Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 70 Nominal Area UX P15 0.6/1KV UX(Class2 Conductor) Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 95 Nominal Area UX P15 0.6/1KV UX(Class2 Conductor) Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 120 Nominal Area UX P15 0.6/1KV UX(Class2 Conductor) Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 150 Nominal Area UX P15 0.6/1KV UX(Class2 Conductor) Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 185 Nominal Area UX P15 0.6/1KV UX(Class2 Conductor) Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 240 Nominal Area UX P15 0.6/1KV UX(Class2 Conductor) Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 300 Nominal Area UX P15 0.6/1KV UX(Class2 Conductor) Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 1.0 Nominal Area UX P15 0.6/1KV FX-UX(Class5 Conductor) Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 1.5 Nominal Area UX P15 0.6/1KV FX-UX(Class5 Conductor) Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 2.5 Nominal Area UX P15 0.6/1KV FX-UX(Class5 Conductor) Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 4 Nominal Area UX P15 0.6/1KV FX-UX(Class5 Conductor) Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 6 Nominal Area UX P15 0.6/1KV FX-UX(Class5 Conductor) Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 10 Nominal Area UX P15 0.6/1KV FX-UX(Class5 Conductor) Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 16 Nominal Area UX P15 0.6/1KV FX-UX(Class5 Conductor) Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 25 Nominal Area UX P15 0.6/1KV FX-UX(Class5 Conductor) Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 35 Nominal Area UX P15 0.6/1KV FX-UX(Class5 Conductor) Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 50 Nominal Area UX P15 0.6/1KV FX-UX(Class5 Conductor) Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 70 Nominal Area UX P15 0.6/1KV FX-UX(Class5 Conductor) Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 95 Nominal Area UX P15 0.6/1KV FX-UX(Class5 Conductor) Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 120 Nominal Area UX P15 0.6/1KV FX-UX(Class5 Conductor) Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 150 Nominal Area UX P15 0.6/1KV FX-UX(Class5 Conductor) Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 185 Nominal Area UX P15 0.6/1KV FX-UX(Class5 Conductor) Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 240 Nominal Area UX P15 0.6/1KV FX-UX(Class5 Conductor) Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 300 Nominal Area UX P15 0.6/1KV FX-UX(Class5 Conductor) Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 1.0 Nominal Area UX P15 0.6/1KV RX Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 1.5 Nominal Area UX P15 0.6/1KV RX Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 2.5 Nominal Area UX P15 0.6/1KV RX Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 4 Nominal Area UX P15 0.6/1KV RX Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 6 Nominal Area UX P15 0.6/1KV RX Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 10 Nominal Area UX P15 0.6/1KV RX Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 16 Nominal Area UX P15 0.6/1KV RX Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 25 Nominal Area UX P15 0.6/1KV RX Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 35 Nominal Area UX P15 0.6/1KV RX Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 50 Nominal Area UX P15 0.6/1KV RX Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 70 Nominal Area UX P15 0.6/1KV RX Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 95 Nominal Area UX P15 0.6/1KV RX Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 150 Nominal Area UX P15 0.6/1KV RX Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 185 Nominal Area UX P15 0.6/1KV RX Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 240 Nominal Area UX P15 0.6/1KV RX Earthing and Bonding Wire Cable Designation Flame Retardant
- Eutex Cable 1 Core 300 Nominal Area UX P15 0.6/1KV RX Earthing and Bonding Wire Cable Designation Flame Retardant
Conductor: Stranded tinned annealed copper wires as per IEC 60228, Class 2
Insulation:
RX: HF EPR as per IEC 60092-351
UX: SHF2 as per IEC 60092-359
Insulation color : Yellow/Green (Green base with yellow strip) or Green
Application Standard:
Design guide: NEK-606 & IEC 60092-353
Flame retardant: EC 60332-1 & IEC 60332-3 Category A
Halogen content: IEC 60754-1, 0.5% ↓
Cold bend / impact: CSA 22.2 No.03 (-40°C/-35°C)
Smoke light transmittance: IEC 61034, 60% ↑
Sunlight (UV) resistant: UL 1581
technical specifications: | |
no. of cores - no. | 1 |
conductor - nominal weight area - (mm2) | 120 |
conductor - max. no. of wires - (ea) | 37 |
conductor - max. overall dia. - (mm) | 14.5 |
thickness of insulation - (mm) | 1.6 |
overall diameter - nominal - (mm) | 17.9 |
overall diameter -tolerance - (±mm) | 1.0 |
conductor resistance (at 20°) (max.) - (Ω/km) | 0.154 |
insulation resistance (at 20°) (min.) - (ΜΩ-km) | 3 |
test voltage - (v/5min.) | 3,500 |
cable weight - (kg/km) | 1,260 |