Helukabel 18 AWG 7 Cores SY-JB Flexible Colour Coded With Steel Wire Braiding Meter Marking Cable 12239

Helukabel 18 AWG 7 Cores SY-JB Flexible Colour Coded With Steel Wire Braiding Meter Marking Cable 12239

Select gauge from drop-down menu for prices:

Helukabel 18 AWG 7 Cores SY-JB Flexible Colour Coded With Steel Wire Braiding Meter Marking Cable 12239

Product Details

Technical Data: 
• Special-PVC control cable adapted to DIN VDE 0285-525-2-51/ DIN EN 50525-2-51

Temperature Range: 
• Flexing -15°C to +80°C
• Fixed installation -40°C to +80°C

Nominal Voltage: 
• Up to 2,5 mm² U0/U 300/500 V 
• From 4,0 mm² U0/U 450/750 V 

Test Voltage: 
• 4000 V

Breakdown Voltage: 
• Min. 8000 V.

Insulation Resistance: 
• Min 20 MOhm x km

Minimum Bending Radius: 
• Flexing 20x cable Ø 
• Fixed installation 6x cable Ø.

Radiation Resistance: 
• Up to 80x106 cJ/kg (up to 80 Mrad)

Cable Structure: 
• Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5
• Core insulation of special PVC compound type Z 7225
• Core identification to JB/OB colour code
• GN-YE conductor, 3 cores and above in the outer layer
• Cores stranded in layers with optimal lay length
• Inner sheath of special PVC
• Galvanized steel wire screening
• Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1/DIN EN 50363-4-1
• Sheath colour transparent with meter marking.

Properties: 
• Extensively oil resistant, oil-/chemical resistance see "Technical Informations"
• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers.

Note: 
• G = with green-yellow conductor x = without green-yellow conductor (OB).
• Further dimensions available on request.
• AWG sizes are approximate equivalent values. The actual cross-section is in mm².
• Screened analogue type: SY-JZ

Application: 
• SY-JB cables are used as measuring and control cables in tool machinery, plant installation, power stations and in data equipment. The braided screen
offers best possible protection against mechanical damage. The galvanized coating on the steel wire braiding not only helps protect against corrosion,
but also notably improves the soldering performance.

technical specification:
awg-no. 18
no.cores x cross-sec. mm² 7 G 1
outer ø approx. mm 10,5
cop. weight kg / km 67,0
weight approx. kg / km 227,0
helukabel part number 12239

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question