Product Details

Technical Data:
• Special-PVC control cable adapted to DIN VDE 0285-525-2-11 / DIN EN 50525-2-11

Temperature Range:
• flexing -15°C to +80°C
• fixed installation -40°C to +80°C

Nominal Voltage:
• U0/U 300/500 V

Test Voltage:
• 4000 V

Breakdown Voltage:
• min. 8000 V

Minimum Bending Radius:
• flexing 7,5x cable Ø
• fixed installation 4x cable Ø

Radiation Resistance:
• up to 80x106 cJ/kg (up to 80 Mrad)

Cable Structure:
• Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5
• Core insulation of special PVC compound type Z 7225
• Core identification to JB/OB colour code
• GN-YE conductor, 3 cores and above in the outer layer
• Cores stranded in layers with optimal lay length
• Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1/DIN EN 50363-4-1
• Sheath colour: grey (RAL 7001)
• With meter marking

Properties:
• Extensively oil resistant, oil-/chemical resistance see "Technical Informations"
• Conditional drag chain compatible
• Conditional suitability for torsion
• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers

Tests:
• PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2

Note:
• G = with GN-YE conductor x = without GN-YE conductor (OB)
• AWG sizes are approximate equivalent values. The actual cross section is in mm².
• Screened analogue type: Y-CY-JB

Application:
For flexible use under medium mechanical stress with free movement without tensile stress and without forced motion control in dry, moist and wet rooms but not suitable for open air as measuring and control cables in machine tools, conveyor belts, production lines, as well as plant engineering, heating and air conditioning.
= Product conforms with Low-Voltage Directive 2014/35/EU.

technical specification:
awg-no. 20
no.cores x cross-sec. mm² 12 G 0,5
outer ø app. - mm 8,7
cop. weight - kg/km 58,0
weight app. - kg/km 135,0
helukabel part number 11013

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question