Conductors: Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used over the conductor.

Insulation: Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580.

Shield: An aluminum/polyester tape with drain wire, 100% coverage, is applied over each twisted pair and the cabled core. The single pair construction has only the overall shield and drain wire.

Jacket: Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) in accordance with the requirements of IEEE- 1580-2010. Thickness as shown in tables on opposite page. Arctic Neoprene (Type N) also available as an option.

Applications
• Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities.
• Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored & sheathed).
• The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3).
• This product may be manufactured in an unarmored or armored and sheathed version.

Features/Ratings
• Superior resistance to oil, abrasion, moisture, sunlight, crush and impact
• High strand count conductors provide superior flexibility
• Higher allowable conductor operating temperature results in increased ampacity
• Cold bend/ cold impact of -40°/ -35°C in accordance with CSA 22.2 No. 0.3
• Flame retardant in accordance with IEEE 1202 and IEC 60332-3-22 Category A
• Meets IEEE standards for 600V and performance requirements of IEC standards for 0.6/1 kV
• Unarmored cables suitable for Class 1, Division 2 and Zone 2 hazardous locations offshore
• Meets the requirements of UL 1277 and UL 1569 for Type TC-ER exposed runs

Approvals
• IEEE 1580 and IEEE 45 - Marine Shipboard Cable
• UL 1309- Marine Shipboard Cable Type X110
• CSA 22.2 No. 245- Marine Shipboard Cable Type X110
• CSA 22.2 No. 239- Type CIC
• CSA 22.2 No. 230- Type TC
• Det Norske Veritas (DNV)
• American Bureau of Shipping (ABS)
• Transport Canada Approved AMS400-20-2
• Transport Canada 8700-20-2
• Lloyd’s Register of Shipping (LRS)
• United States Coast Guard-46CFR

Technical Specification
Conductor Size 18 AWG 
Number of Triads 5
Insulation Thickness in .030
Insulation Thickness mm 0.76
Sheath Thickness in 0.060
Sheath Thickness mm 1.5
Cable Diameter (Nominal) in 0.780
Cable Diameter (Nominal) mm 19.8
Cable Weight (Approximate)lbs/mft 315
Cable Weight (Approximate)kg/km 470
Type Designation TT(I/S-0S)18PN-5
Prysmian and Draka Part Number T26459